Evidence map›Paper›PMID 40673710›Full record

ArticleJournal of synchrotron radiation2025

A high throughput and micrometre spatial resolution design for a versatile resonant inelastic X-ray scattering spectrometer.

Ruijie Wang, Pengjun Zhang, Qingchen Li, Yujian Xia, Lisheng Qian, Xuefei Feng, Shuangming Chen, Xiaosong Liu

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ruijie WangNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.
Pengjun ZhangNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.
Qingchen LiDepartment of Optics and Optical Engineering, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
Yujian XiaNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.
Lisheng QianNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.ORCID 0009-0004-9574-2599
Xuefei FengNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.
Shuangming ChenNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.ORCID 0000-0001-7567-1552
Xiaosong LiuNational Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.ORCID 0000-0003-1798-0730

Funding

National Key Research and Development Program of China 2022YFA1605400National Key Research and Development Program of China 2023YFF0716103National Natural Science Foundation of China 12205303National Natural Science Foundation of China 12322515
6 · The paper itself

Abstract

A versatile scheme has been meticulously engineered for a resonant inelastic X-ray scattering spectrometer, enabling free switching between high throughput configurations with narrow spatial-resolution and low throughput setups boasting broad spatial-resolution capabilities. The high throughput mode enhances signal intensity threefold compared with setups with only the dispersive subassembly, while achieving 2.7 µm resolution within a 16 µm range. Alternatively, the broad spatial-resolution mode achieves 2.7 µm resolution across the entire optical footprint. Furthermore, the incorporation of specialized mirrors not only facilitates focusing but also paves the way for potential enhancements to the strip-shaped detector, thereby augmenting its resolution. By employing a vertically compact beam spot in conjunction with the Hettrick-Underwood optical configuration, this spectrometer attains a resolving power surpassing 12000 for 284-780 eV. This work provides an exhaustive exploration of the multifaceted attributes to the spectrometer's optical design, highlighting its adaptability and high performance in diverse experimental scenarios.

Indexed as

resonant inelastic X-ray scattering spectroscopysoft X-ray spectrometersynchrotron radiation

Identifiers

PMID40673710
PMCPMC12416433

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.