ArticleJournal of synchrotron radiation2025
A high throughput and micrometre spatial resolution design for a versatile resonant inelastic X-ray scattering spectrometer.
Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
A versatile scheme has been meticulously engineered for a resonant inelastic X-ray scattering spectrometer, enabling free switching between high throughput configurations with narrow spatial-resolution and low throughput setups boasting broad spatial-resolution capabilities. The high throughput mode enhances signal intensity threefold compared with setups with only the dispersive subassembly, while achieving 2.7 µm resolution within a 16 µm range. Alternatively, the broad spatial-resolution mode achieves 2.7 µm resolution across the entire optical footprint. Furthermore, the incorporation of specialized mirrors not only facilitates focusing but also paves the way for potential enhancements to the strip-shaped detector, thereby augmenting its resolution. By employing a vertically compact beam spot in conjunction with the Hettrick-Underwood optical configuration, this spectrometer attains a resolving power surpassing 12000 for 284-780 eV. This work provides an exhaustive exploration of the multifaceted attributes to the spectrometer's optical design, highlighting its adaptability and high performance in diverse experimental scenarios.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.