ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2026
Extracorporeal Support Vascular Access: 3D Printing Custom Cannulas.
Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
Extracorporeal life support (ECLS) requires specialized cannulas for vascular access that are dependent on each patient's needs, size, and unique vascular anatomy. There are currently no commercially available drainage cannulas suitable for patients smaller than 1.5 kg. This study presents the development of a novel 6 Fr cannula for blood drainage to be used in these small patients. Cannulas were manufactured using stereolithography three-dimensional (3D) printing on Form 3 and Form 3B printers and tested in vitro using 3% glycerol. Drainage pressure at 100 ml/min was -39 ± 2 and -42.3 ± 9 mm Hg, for Form 3 and Form 3B, respectively. Maximum flow rate and drainage pressures were 185.8 ± 15 ml/min and -80 ± 2 mm Hg and 165 ± 21 ml/min and -85.7 ± 12 mm Hg for Form 3 and Form 3B, respectively. Three Form 3B cannulas were tested in vivo in an ECLS piglet model, the best of which had a maximum blood flow rate of 139 ml/min at -32 mm Hg drainage pressure. Cannulas 3D-printed using the Form 3 and Form 3B printers exhibited appropriate size and flow rates (~100 ml/kg/min) for ECLS needed to support premature patients with minimal complexity in the fabrication process. These cannulas should be optimized in preclinical research using translational models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.