Evidence map›Paper›PMID 40671130›Full record

ArticleJournal of orthopaedic surgery and research2025

Biomechanical evaluation of In-Out-In pedicle screws for atlantoaxial posterior fixation in the presence of high-riding vertebral artery and narrow C2 pedicles: a finite element analysis.

Xiong-Han Lian, Wen He, Wen-Jia Sun, Xu-Chao Lin, Huo-Huo Xue, Zhi-Feng Zeng, Yu-Fan Chen, Ming-di Chen, Feng-Guang Wei, Zhi-Qiang Wang and 5 more

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Xiong-Han LianFuzhou Second General Hospital, Fuzhou, 350007, China.
Wen HeFuzhou Second General Hospital, Fuzhou, 350007, China.
Wen-Jia SunFuzhou Second General Hospital, Fuzhou, 350007, China.
Xu-Chao LinFuzhou Second General Hospital, Fuzhou, 350007, China.
Huo-Huo XueFuzhou Second General Hospital, Fuzhou, 350007, China.
Zhi-Feng ZengFuzhou Second General Hospital, Fuzhou, 350007, China.
Yu-Fan ChenFuzhou Second General Hospital, Fuzhou, 350007, China.
Ming-di ChenFuzhou Second General Hospital, Fuzhou, 350007, China.
Feng-Guang WeiFuzhou Second General Hospital, Fuzhou, 350007, China.
Zhi-Qiang WangFuzhou Second General Hospital, Fuzhou, 350007, China.
Hong-Liang RuanFuzhou Second General Hospital, Fuzhou, 350007, China.
Zi-Qi LuoFuzhou Second General Hospital, Fuzhou, 350007, China.
Xiang-Ting ChenFuzhou Second General Hospital, Fuzhou, 350007, China.
Xin ChenFuzhou Second General Hospital, Fuzhou, 350007, China.
Jing-Lai XueFuzhou Second General Hospital, Fuzhou, 350007, China. xuejinglai@163.com.

Funding

Fujian Provincial Clinical Medical Research Center for First Aid and Rehabilitation in Orthopaedic Trauma 2020Y2014Fujian Provincial Natural Science Foundation Project 2022J011312
6 · The paper itself

Abstract

introductionIn patients with high-riding vertebral artery (HRVA) and narrow pedicles, placement of C2 pedicle screws carries a significant risk of vertebral artery injury. The in-out-in pedicle screws (IOIPS) technique offers an alternative posterior fixation strategy. However, the biomechanical performance remains unclear.

methodsA finite element model of the upper cervical spine (C0-C2) was developed to simulate HRVA and narrow pedicles. All posterior fixation constructs utilized C1 pedicle screws, while four different techniques were applied to C2: IOIPS, pedicle screws, pars screws, and translaminar screws. A vertical load of 50 N and a torque of 1.5 Nm were applied at C0 to assess and compare the range of motion (ROM) and stress distribution.

resultsAll four fixation techniques effectively reduced ROMs at the atlantoaxial, with IOIPS demonstrating the lowest ROMs and translaminar screws showing the highest. Pedicle and pars screws exhibited higher von Mises stresses within the implants, while IOIPS achieved a more uniform stress distribution. Translaminar screws had the lowest implant stresses but provided the least stability.

conclusionFor patients with HRVA and narrow C2 pedicles, IOIPS offers superior stability along with relatively low and evenly distributed implant stress, suggesting it is a biomechanically viable fixation technique. However, its application should be reserved for carefully selected cases rather than adopted as a routine surgical strategy.

Indexed as

Atlanto-Axial JointCervical VertebraeFinite Element AnalysisPedicle ScrewsSpinal FusionVertebral ArteryBiomechanical PhenomenaHumansRange of Motion, ArticularAtlantoaxialBiomechanicsFinite element analysisPedicle screwPosterior fixation

Identifiers

PMID40671130
PMCPMC12269112

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.