Evidence map›Paper›PMID 40670955›Full record

ArticleBMC pregnancy and childbirth2025

Comparative study of 2D vs. 3D AI-enhanced ultrasound for fetal crown-rump length evaluation in the first trimester.

Yuanji Zhang, Yuhao Huang, Chaoyu Chen, Xing Hu, Wenxiong Pan, Huanjia Luo, Yankai Huang, Haixia Wang, Yan Cao, Yan Yi and 2 more

Abstract readComparative Study
In one paragraph

Article in BMC pregnancy and childbirth, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Yuanji ZhangNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China.
Yuhao HuangNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China.
Chaoyu ChenNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China.
Xing HuDepartment of Ultrasound, Shenzhen Luohu People's Hospital, Third Affiliated Hospital of Shenzhen University, Shenzhen, China.
Wenxiong PanSchool of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
Huanjia LuoDepartment of Ultrasound, Huizhou Central People's Hospital, Huizhou, Guangdong, China.
Yankai HuangDepartment of Ultrasound, Southern Medical University Shenzhen Hospital, Shenzhen, China.
Haixia WangDepartment of Ultrasound, Shenzhen Luohu People's Hospital, Third Affiliated Hospital of Shenzhen University, Shenzhen, China.
Yan CaoShenzhen RayShape Medical Technology Co., Ltd, Shenzhen, Guangdong, China.
Yan YiDepartment of Ultrasound, Shenzhen People's Hospital, Shenzhen, China. yiyan1977@126.com.
Yi XiongDepartment of Ultrasound, Shenzhen Luohu People's Hospital, Third Affiliated Hospital of Shenzhen University, Shenzhen, China. 13352995536@163.com.
Dong NiNational-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China. nidong@szu.edu.cn.

Funding

Guangdong Province Key Areas Research and Development Program Project No.2020B1111130002Guangxi Key Research and Development Program No. 2022AB11073National Natural Science Foundation of China No. 62171290Science and Technology Planning Project of Guangdong Province, China No.2023A0505020002
6 · The paper itself

Abstract

backgroundAccurate fetal growth evaluation is crucial for monitoring fetal health, with crown-rump length (CRL) being the gold standard for estimating gestational age and assessing growth during the first trimester. To enhance CRL evaluation accuracy and efficiency, we developed an artificial intelligence (AI)-based model (3DCRL-Net) using the 3D U-Net architecture for automatic landmark detection to achieve CRL plane localization and measurement in 3D ultrasound. We then compared its performance to that of experienced radiologists using both 2D and 3D ultrasound for fetal growth assessment. MATERIALS AND

methodsThis prospective consecutive study collected fetal data from 1,326 ultrasound screenings conducted at 11-14 weeks of gestation (June 2021 to June 2023). Three experienced radiologists performed fetal screening using 2D video (2D-RAD) and 3D volume (3D-RAD) to obtain the CRL plane and measurement. The 3DCRL-Net model automatically outputs the landmark position, CRL plane localization and measurement. Three specialists audited the planes achieved by radiologists and 3DCRL-Net as standard or non-standard. The performance of CRL landmark detection, plane localization, measurement and time efficiency was evaluated in the internal testing dataset, comparing results with 3D-RAD. In the external dataset, CRL plane localization, measurement accuracy, and time efficiency were compared among the three groups.

resultsThe internal dataset consisted of 126 cases in the testing set (training: validation: testing = 8:1:1), and the external dataset included 245 cases. On the internal testing set, 3DCRL-Net achieved a mean absolute distance error of 1.81 mm for the nine landmarks, higher accuracy in standard plane localization compared to 3D-RAD (91.27% vs. 80.16%), and strong consistency in CRL measurements (mean absolute error (MAE): 1.26 mm; mean difference: 0.37 mm, P = 0.70). The average time required per fetal case was 2.02 s for 3DCRL-Net versus 2 min for 3D-RAD (P < 0.001). On the external testing dataset, 3DCRL-Net demonstrated high performance in standard plane localization, achieving results comparable to 2D-RAD and 3D-RAD (accuracy: 91.43% vs. 93.06% vs. 86.12%), with strong consistency in CRL measurements, compared to 2D-RAD, which showed an MAE of 1.58 mm and a mean difference of 1.12 mm (P = 0.25). For 2D-RAD vs. 3DCRL-Net, the Pearson correlation and R² were 0.96 and 0.93, respectively, with an MAE of 0.11 ± 0.12 weeks. The average time required per fetal case was 5 s for 3DCRL-Net, compared to 2 min for 3D-RAD and 35 s for 2D-RAD (P < 0.001).

conclusionsThe 3DCRL-Net model provides a rapid, accurate, and fully automated solution for CRL measurement in 3D ultrasound, achieving expert-level performance and significantly improving the efficiency and reliability of first-trimester fetal growth assessment.

Indexed as

Artificial IntelligenceCrown-Rump LengthFetal DevelopmentImaging, Three-DimensionalUltrasonography, PrenatalAdultFemaleGestational AgeHumansPregnancyPregnancy Trimester, FirstProspective StudiesArtificial intelligenceCRL evaluationCrown-rump lengthFetal growth

Identifiers

PMID40670955
PMCPMC12265274

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.