ArticleFrontiers in bioengineering and biotechnology2025

Biomechanical and clinical comparison of different prosthetic in reconstruction following total

Zhangui Gu, Long Ma, Qiang Liu, Kun Wang, Zongqiang Yang, Ningkui Niu, Jiandang Shi

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Is preoperative cervical range of motion associated with cage subsidence after anterior cervical discectomy and fusion?European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhangui Gu *Department of Orthopedic, General Hospital of Ningxia Medical University, Yinchuan, China.
Long Ma *Department of Orthopedic, General Hospital of Ningxia Medical University, Yinchuan, China.
Qiang Liu *Department of Orthopedic, General Hospital of Ningxia Medical University, Yinchuan, China.
Kun WangFirst Clinical Medical College of Ningxia Medical University, Yinchuan, China.
Zongqiang YangDepartment of Orthopedic, General Hospital of Ningxia Medical University, Yinchuan, China.
Ningkui NiuDepartment of Orthopedic, General Hospital of Ningxia Medical University, Yinchuan, China.
Jiandang ShiDepartment of Orthopedic, General Hospital of Ningxia Medical University, Yinchuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: To analyze and compare the biomechanical differences and clinical efficacy of artificial vertebral bodies (AVBs) versus traditional titanium mesh cages (TMCs) reconstruction following total Materials and Methods: Finite Element Analysis: A finite element model of T12-L5 vertebrae from a healthy adult was utilized to construct two reconstruction models following L2 TES: Group A (AVB) and Group B (TMC). Using ANSYS software, flexion-extension, lateral bending, and axial rotation loading conditions were simulated to comparatively analyze stress distribution at the prosthesis-endplate interface and biomechanical characteristics of the fixation system; Clinical research: This retrospective study included 20 thoracolumbar tumor patients who underwent posterior TES at our institution from January 2014 to October 2024, divided into AVBs ( Results: Finite element analysis revealed that the TMC model exhibited significant stress concentration phenomena across all motion modes compared to the AVB model. Specifically, the stress on the L1 inferior endplate was 50.09%, 17.48%, 74.07%, 133.83%, and 87.23% higher during extension, left lateral bending, right lateral bending, left axial rotation, and right axial rotation, respectively. The L3 superior endplate demonstrated similar stress patterns but with smaller magnitudes. In both implant models, peak stresses occurred during extension and axial rotation, followed by lateral bending, with minimal stress observed during flexion. For the posterior fixation system, no significant differences in maximum stress were observed between the two prosthetic configurations; Clinically, Group A demonstrated significantly lower implant subsidence rates (10% vs 70%) and superior outcomes in intervertebral height loss (1.33 ± 0.82 mm vs 12.36 ± 7.79 mm) and angular loss ( Conclusion: Following TES, the AVB demonstrated more uniform stress distribution and superior biomechanical performance compared to the TMC. Additionally, the AVB effectively reduced implant subsidence rates, maintained intervertebral height, corrected kyphotic deformities, and exhibited enhanced biomechanical stability and clinical efficacy.

Indexed as

artificial vertebral bodiesclinical researchfinite element analysistitanium mesh cagetotal en bloc spondylectomy

Identifiers

PMID40666701
PMCPMC12259587

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.