Evidence map›Paper›PMID 40666077›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2025

Understanding the impact of patient-specific geometries on Cherenkov emission-to-dose relationship during External Beam Radiation Therapy (EBRT).

Baozhu Lu, Brook Byrd, Yifeng Zhu, Daniel Alexander, John P Plastaras, Taoran Li, Lisha Chen, Brian W Pogue, Timothy C Zhu

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Baozhu LuDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Brook ByrdDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Yifeng ZhuDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Daniel AlexanderDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
John P PlastarasDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Taoran LiDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Lisha ChenDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Brian W PogueDepartment of Medical Physics, University of Wisconsin-Madison, Hanover, NH, USA.
Timothy C ZhuDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.

Funding

Cherenkov imaging incorporating 3D surface imaging for TSETR01CA274411 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ZHU, TIMOTHY C. · 2022 to 2025
$2.1M
Cherenkov imaging of Total Skin Electron Therapy (TSET)R21CA239127 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ZHU, TIMOTHY C. · 2020 to 2021
$386k
NCI NIH HHS R01 CA274411NCI NIH HHS R21 CA239127
6 · The paper itself

Abstract

Cherenkov photons generated during External Beam Radiation Therapy (EBRT) provide real-time optical feedback on the radiation field distribution. While Cherenkov emission correlates with radiation dose, patient-specific anatomical variations, particularly breast geometry, introduce inconsistencies in the Cherenkov emission-to-dose ratio. This study investigates the influence of breast contour, specifically curvature, on the accuracy of Cherenkov-based dosimetry. To address these variations, patient-specific Cherenkov imaging data is corrected using Lambertian geometric correction and compared with the planned radiation dose to derive a correction function as a function of breast curvature. Additionally, scintillator-based Cherenkov imaging data is analyzed and compared with in vivo dosimetry to assess the feasibility of scintillators as real-time dosimeters for EBRT.

Indexed as

Cherenkov imagingCurvatureDose monitoring and optimizationExternal Beam Radiation TherapyReal-time dosimetryScintillator-based detection

Identifiers

PMID40666077
PMCPMC12263119

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.