Optimization and validation of a mechanical compression model for digital breast phantoms in mammography and tomosynthesis simulations.

Gustavo Pacheco, Koen Michielsen, Eloy García, Oliver Díaz, Ioannis Sechopoulos

Abstract readValidation Study
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Gustavo PachecoDepartment of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.
Koen MichielsenDepartment of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.
Eloy GarcíaInstitute of Computer Vision and Robotics (ViCOROB), University of Girona, Girona, Spain.
Oliver DíazFacultat de Mahemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain.
Ioannis SechopoulosDepartment of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.

Funding

AIMED PID2023-146786OB-I00IMPACT 19403
6 · The paper itself

Abstract

backgroundBreast positioning and compression are integral to digital mammography (DM) and digital breast tomosynthesis (DBT) imaging. Therefore, their accurate representation in computer simulations using anthropomorphic digital breast phantoms can be crucial. However, existing compression models often neglect external conditions, such as breast support elevation and radiographer handling, and lack quantitative validation against reference compressed breast shapes. PURPOSE: To optimize and validate a finite element compression model for digital breast phantoms in the cranio-caudal (CC) view using a statistical shape model derived from patient structured light (SL) scans.

methodsUncompressed breast phantoms were generated from segmented dedicated breast CT scans of 88 patients. A subset of 30 phantoms was selected to balance representativeness and computational efficiency. Simulated compression was performed using a finite element solver while varying combinations of adipose tissue, fibroglandular tissue, and skin Young's moduli, breast support height, and positioning force magnitudes. After compression, principal component analysis (PCA) was performed on the phantom surfaces, and shape feature distributions were compared to those from 236 compressed patient breasts acquired via structured light (SL) scanning. A weighted Kolmogorov-Smirnov (K-S) distance was used to quantify shape agreement through the distance between the phantom and patient shape feature distributions. A multi-stage optimization strategy combining random sampling and grid searches was used to minimize this distance and identify physiologically plausible parameter ranges.

resultsThe optimized parameter set improved agreement between phantom and patient shape feature distributions, reducing the average K-S distance from 0.50 to 0.32. External conditions, namely the breast support elevation and positioning forces, had a greater impact on agreement than elastic parameters. The analysis identified physiologically plausible parameter ranges that consistently produced realistic shapes. Tissue elastic parameters had a smaller but measurable effect and the results highlighted the importance of modeling skin as a distinct tissue type.

conclusionsThis study highlights the importance of external forces and boundary conditions in achieving realistic compressed breast shapes and provides validated parameter ranges for compression simulations. The proposed intervals can serve as a basis for introducing variability in virtual clinical trials and other digital phantom studies. Further research should extend validation to internal tissue distribution and MLO compression.

Indexed as

BreastMammographyMechanical PhenomenaPhantoms, ImagingFemaleFinite Element AnalysisHumansbreast compressiondigital breast phantomsvirtual clinical trials

Identifiers

PMID40665594
PMCPMC12279004

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.