Evidence map›Paper›PMID 40665522›Full record

ArticleMedical physics2025

A viscous fluid model for large-scale motion estimation in image-guided radiotherapy.

Tom J W Draper, Cornel Zachiu, Bas W Raaymakers

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tom J W DraperDepartment of Radiotherapy, UMC Utrecht, Utrecht, The Netherlands.
Cornel ZachiuDepartment of Radiotherapy, UMC Utrecht, Utrecht, The Netherlands.
Bas W RaaymakersDepartment of Radiotherapy, UMC Utrecht, Utrecht, The Netherlands.

Funding

Health ∼ Holland (LSH) DARE project
6 · The paper itself

Abstract

backgroundImage-guided radiotherapy (IGRT) is often hampered by geometric inaccuracies introduced by anatomical and physiological motion. Although a wide array of deformable image registration (DIR) solutions have been proposed toward motion estimation and compensation during IGRT, their accuracy and precision generally deteriorates within areas showcasing particularly large displacements such as the thorax, abdomen and pelvis. PURPOSE: In this work, we propose a physics-derived DIR algorithm for motion estimation during IGRT, designed to be specifically suitable for highly deforming anatomical areas. The proposed solution also has a single configuration parameter controlling the volumetric deformations of the anatomy and a high computational performance, lending it particularly compatible with online adaptive workflows.

methodsWe hereby address the DIR problem by modeling anatomical motion as the flow of a viscous fluid. In this context, we solve a simplified form of the Navier-Stokes equations where the dissimilarity between the registered images plays the role of actuating force. The high degree-of-freedom of the solutions resulting from viscous fluid dynamics thereby allows for the estimation of large-scale deformations. For computational purposes, a highly parallelizable FFT-based numerical solver was used, allowing for its seamless implementation on graphical processing units. The Jacobian determinant was used to analyze tissue compression and expansion at a voxel-wise level and to identify implausible deformations. The accuracy and precision of the proposed algorithm was analyzed for thoracic CT and pelvic MR images showcasing particularly large deformations. A gold standard consisting of annotated landmarks was available for the CT images, while for the MR data manually-approved contours were generated using a semi-automatic procedure.

resultsThe proposed DIR solution showcased an overall accuracy of 1 - 2 mm for the thoracic CT data and a Dice similarity coefficient of 0.8 - 0.9 for the contours defined on the MR images. Moreover, the model estimates motion with a smooth distribution of the Jacobian determinant. The average computational latency ranged between 20 s to 3.5 min, dependent on the size of the registered images.

conclusionsIn this work, we have formulated the DIR problem under the shape of a system of equations describing the dynamics of a viscous fluid. The algorithm demonstrated capabilities for estimating large deformations in the thorax and pelvis for both CT and MR images, with an accuracy and precision in line with recommendations for clinical acceptability. Together with its computational performance, this could make it an attractive solution for motion management during online IGRT.

Indexed as

HydrodynamicsRadiotherapy, Image-GuidedAlgorithmsHumansImage Processing, Computer-AssistedMovementViscositydeformable image registrationfluid regularizationimage‐guided radiotherapy

Identifiers

PMID40665522
PMCPMC12264329

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.