ArticleMedical physics2025
Feasibility of a real-time dual energy markerless monitoring of lung tumors using a clinical room-mounted stereoscopic and monoscopic x-ray imaging system.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
backgroundThe motion of lung tumors during breathing poses challenges in stereotactic body radiotherapy (SBRT), warranting improved monitoring techniques. Breathing complicates SBRT by creating positional uncertainty in the lungs, traditionally managed with PTV margins, respiratory gating, or breath hold, each with significant drawbacks. While external and implanted markers for tracking have limitations, dual energy (DE) imaging offers a noninvasive, markerless solution that enhances soft tissue contrast and improves real-time tumor localization accuracy and precision. PURPOSE: This study aims to develop a markerless real-time DE tumor localization technique on a clinical room-mounted x-ray image guidance system to allow precise 3D stereoscopic and monoscopic lung tumor motion monitoring during radiotherapy.
methodsA motorized programmable breathing phantom combined with an anthropomorphic phantom was developed to simulate a lung tumor's respiratory motion, with various asymmetric 3D printed tumor models from lung patients. Tumor sizes ranged between 1.0 and 3.3 cm, with some having varying densities and imaged with varying doses. Real-time images were acquired with a clinical ExacTrac stereoscopic imaging system at a rate of 1.67 Hz with high and low energies (140 and 60 kVp). Weighted logarithmic subtraction and an anti-correlated noise reduction algorithm were used to generate DE images. Conventional single energy images (120 kVp) were acquired for comparison. Digital reconstructed radiographs from x-ray imaging views were created to serve as templates for a template-matching algorithm developed to localize tumor locations on x-ray views. For the stereoscopic case where both imaging views were available, 3D triangulation was performed to localize the tumor. In the monoscopic case, when only one x-ray view was available, the 3D tumor position was estimated using a single 2D localization, combined with a 3D probability density function (PDF) describing tumor motion.
resultsStereoscopic DE techniques demonstrated accurate localizations. The monoscopic view obstructed by the spine showed lower success rates than the view obstructed only by the rib bone. In stereoscopic cases, the localization success rates were similar (>96%) between single and DE techniques for large tumor sizes. As tumor sizes decreased, the localization success rates were higher for DE than the single energy technique showing an improvement of up to 25%. Monoscopic results demonstrated the same trend, with DE localization success rates improvement versus single energy by up to 53% for small tumors. DE showed more successful localization for less dense tumors by up to 60% compared to single energy. Tumors imaged with varying mAs values while remaining at optimal kVp settings showed similar localization success rates between single and DE techniques.
conclusionA real-time markerless tumor monitoring technique was developed utilizing a clinical room-mounted stereoscopic/monoscopic image guidance system. DE increases the accuracy of successful tumor localization as compared to the conventional single energy approach, especially for smaller, less dense tumors. The use of PDFs may be a viable approach to monoscopic estimates when only one view is available.