Evidence map›Paper›PMID 40665506›Full record

ArticleMedical physics2025

Feasibility of a real-time dual energy markerless monitoring of lung tumors using a clinical room-mounted stereoscopic and monoscopic x-ray imaging system.

Zakary McLure, Chris Peacock, Mike Sattarivand

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Zakary McLureDepartment of Physics & Atmospheric Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
Chris PeacockDepartment of Medical Physics, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
Mike SattarivandDepartment of Physics & Atmospheric Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.

Funding

ACOA (Atlantic Canada Opportunities Agency) Atlantic Innovation Fund, Nova Scotia Health, and Dalhousie University
6 · The paper itself

Abstract

backgroundThe motion of lung tumors during breathing poses challenges in stereotactic body radiotherapy (SBRT), warranting improved monitoring techniques. Breathing complicates SBRT by creating positional uncertainty in the lungs, traditionally managed with PTV margins, respiratory gating, or breath hold, each with significant drawbacks. While external and implanted markers for tracking have limitations, dual energy (DE) imaging offers a noninvasive, markerless solution that enhances soft tissue contrast and improves real-time tumor localization accuracy and precision. PURPOSE: This study aims to develop a markerless real-time DE tumor localization technique on a clinical room-mounted x-ray image guidance system to allow precise 3D stereoscopic and monoscopic lung tumor motion monitoring during radiotherapy.

methodsA motorized programmable breathing phantom combined with an anthropomorphic phantom was developed to simulate a lung tumor's respiratory motion, with various asymmetric 3D printed tumor models from lung patients. Tumor sizes ranged between 1.0 and 3.3 cm, with some having varying densities and imaged with varying doses. Real-time images were acquired with a clinical ExacTrac stereoscopic imaging system at a rate of 1.67 Hz with high and low energies (140 and 60 kVp). Weighted logarithmic subtraction and an anti-correlated noise reduction algorithm were used to generate DE images. Conventional single energy images (120 kVp) were acquired for comparison. Digital reconstructed radiographs from x-ray imaging views were created to serve as templates for a template-matching algorithm developed to localize tumor locations on x-ray views. For the stereoscopic case where both imaging views were available, 3D triangulation was performed to localize the tumor. In the monoscopic case, when only one x-ray view was available, the 3D tumor position was estimated using a single 2D localization, combined with a 3D probability density function (PDF) describing tumor motion.

resultsStereoscopic DE techniques demonstrated accurate localizations. The monoscopic view obstructed by the spine showed lower success rates than the view obstructed only by the rib bone. In stereoscopic cases, the localization success rates were similar (>96%) between single and DE techniques for large tumor sizes. As tumor sizes decreased, the localization success rates were higher for DE than the single energy technique showing an improvement of up to 25%. Monoscopic results demonstrated the same trend, with DE localization success rates improvement versus single energy by up to 53% for small tumors. DE showed more successful localization for less dense tumors by up to 60% compared to single energy. Tumors imaged with varying mAs values while remaining at optimal kVp settings showed similar localization success rates between single and DE techniques.

conclusionA real-time markerless tumor monitoring technique was developed utilizing a clinical room-mounted stereoscopic/monoscopic image guidance system. DE increases the accuracy of successful tumor localization as compared to the conventional single energy approach, especially for smaller, less dense tumors. The use of PDFs may be a viable approach to monoscopic estimates when only one view is available.

Indexed as

Lung NeoplasmsFeasibility StudiesHumansImaging, Three-DimensionalMovementPhantoms, ImagingRadiosurgeryRadiotherapy, Image-GuidedRespirationTime Factorsdual energy x‐ray imagingmarkerless trackingstereoscopic/monoscopic IGRT

Identifiers

PMID40665506
PMCPMC12264325

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.