A study on postural care after macular hole surgery based on a novel positioning sensor.

Wenbo Li, Meng Yang, Naxin Duan, Zetong Nie, Zhaoxiong Wang, Xiang Zhang, Boshi Liu, Xiaorong Li, Bojie Hu

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Wenbo Li *Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, China, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
Meng Yang *Tianjin TEDA Hospital, Tianjin, China.
Naxin Duan *Characteristic Medical Center of Chinese People's Armed Police Force, Tianjin, China.
Zetong NieTianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, China, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
Zhaoxiong WangDepartment of Ophthalmology, Tianjin Medical University Baodi Hospital, Tianjin, China.
Xiang ZhangTianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, China, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
Boshi LiuTianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, China, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
Xiaorong LiTianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, China, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
Bojie HuTianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, China, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China. bhu07@tmu.edu.cn.

Funding

The Science&Technology Development Fund of Tianjin Education Commission for Higher Education No.2022ZD058Tianjin Binhai New Area Health Commission Project No. 2023BWKZ006Tianjin Key Medical Discipline (Specialty) Construction Project TJYXZDXK-037A
6 · The paper itself

Abstract

To investigate the application of a postoperative positioning sensor device with real-time dynamic feedback after idiopathic macular hole (IMH) surgery and the distribution of the effective prone time during the postoperative period. Postoperatively, all patients were instructed to wear the positioning sensor for 1 day. The cumulative time in the effective prone position was recorded. Among 18 included participants, the mean total effective face-down position (FDP) time was 9.3 h (SD = 4.0). In the first and last 12 h, the median effective FDP times were 7.1 (4.9, 8.4) and 2.4 (0.2, 4.0) (Z = - 3.720, p < 0.001) hours, respectively. In the first, middle, and last 8 h, the effective FDP times were 5.1 (4.1, 5.7), 2.6 (1.2, 4.6), and 0.9 (0.3, 3.2) hours, respectively (H = 20.24, p < 0.001). The first 8 h differed significantly from both the middle (p = 0.006) and the last 8 h (p < 0.001). The questionnaires indicated positive acceptance of the device. The novel device provided great help for postoperative care of patients and produced significant differences in effective prone time distributions within 1 day.

Indexed as

Patient PositioningPostoperative CarePostureRetinal PerforationsAgedFemaleHumansMaleMiddle AgedPostoperative PeriodProne PositionVitrectomyFace-down positionIdiopathic macular holePositioning sensor devicePostoperative careVitrectomy

Identifiers

PMID40665039
PMCPMC12264045

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.