Evidence map›Paper›PMID 40664866›Full record

ArticleEuropean radiology2026

Splanchnic hemodynamic parameters measured with 4D flow MRI can diagnose severe portal hypertension.

Octavia Bane, Amine Geahchan, Daniel Stocker, Swathi Pavuluri, Ghadi Abboud, Paul Kennedy, Himanshu Sharma, Stefanie J Hectors, Swan Thung, Ning Jin and 5 more

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Octavia BaneDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA. octavia.bane@mountsinai.org.ORCID http://orcid.org/0000-0003-1315-5848
Amine GeahchanDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Daniel StockerDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Swathi PavuluriBioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Ghadi AbboudDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Paul KennedyDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Himanshu SharmaDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Stefanie J HectorsDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Swan ThungDepartment of Pathology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Ning JinSiemens Healthineers, Solon, OH, USA.
Aaron FischmanDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Michael MarklDepartment of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA.
Scott ReederDepartment of Radiology, University of Wisconsin Madison, Madison, WI, USA.
Thomas D SchianoRecanati-Miller Transplantation Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Bachir TaouliDepartment of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.

Funding

Division of Diabetes, Endocrinology, and Metabolic Diseases 5R01DK113272
6 · The paper itself

Abstract

objectivesTo assess the diagnostic performance of splanchnic hemodynamic parameters measured with 4D flow MRI for diagnosis of severe portal hypertension (PH; hepatic venous pressure gradient (HVPG) ≥ 12 mmHg), and prediction of liver decompensation in patients with chronic liver disease. MATERIALS AND

methodsOur single-center prospective study (2018-2022) enrolled patients undergoing transjugular liver biopsy with wedge HVPG measurement for abdominal 4D flow MRI (MRI-HVPG interval = 28 ± 18 (1-78) days). 4D flow MRI was acquired at 1.5 T, 10 min. after injection of gadoxetic acid, with a prototype sequence in coronal-oblique orientation (VENC = 60 cm/s). Multiple observers manually segmented the portal, superior mesenteric, splenic and middle hepatic veins, supraceliac aorta, celiac trunk, hepatic and splenic arteries. Time-averaged vessel cross-section area, through-plane time-averaged velocity and flow, and peak velocity were compared between patients with/without severe PH, and with/without future liver decompensation by Mann-Whitney U test and ROC analysis.

results50 patients (M/F: 26/24, age = 52 ± 15 years) were included, of which 47 had clinical follow-up 1084 ± 618 days after MRI. Twenty-three of 50 (46%) patients had PH, 8/50 (16%) had severe PH, and 12/47 (26%) had decompensation. Celiac trunk peak velocity [AUC (95% CI) = 0.90 (0.80-0.99)] and superior mesenteric vein area [AUC (95% CI) = 0.88 (0.77-0.99)] identified severe PH with the highest diagnostic performance. A logistic regression model combining celiac trunk peak velocity and superior mesenteric vein flow identified severe PH with AUC (95% CI) = 0.95 (0.88-1.00), sensitivity = 100%, specificity = 89%. Hepatic [AUC (95% CI) = 0.74 (0.57-0.92)] and splenic artery [AUC (95% CI) = 0.74 (0.52-0.96)] area, celiac trunk [AUC (95% CI) = 0.70 (0.51-0.89)] and superior mesenteric vein [AUC (95% CI) = 0.72 (0.55-0.89)] flow predicted liver decompensation with good diagnostic performance.

conclusionSplanchnic 4D flow MRI measurements have excellent performance for diagnosing severe PH and good performance for predicting liver decompensation. KEY POINTS: Question Noninvasive detection of severe portal hypertension (hepatic venous pressure gradient ≥ 12 mmHg) is important to prevent bleeding, decompensation, and death in patients with chronic liver disease. Findings Splanchnic hemodynamic measurements by 4D flow MRI can identify patients with severe portal hypertension and predict liver decompensation with excellent/good diagnostic performance. Clinical relevance 4D flow MRI can potentially be integrated into the clinical MRI protocols of patients with liver cirrhosis.

Indexed as

End Stage Liver DiseaseHypertension, PortalLiver CirrhosisMagnetic Resonance ImagingSplanchnic CirculationAdultAgedFemaleFollow-Up StudiesHemodynamicsHumansMaleMiddle AgedProspective StudiesRisk AssessmentSeverity of Illness IndexMagnetic resonance imagingPortal hypertensionSplanchnic circulation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.