ArticleJournal of vascular surgery cases and innovative techniques2025
Computer-assisted vacuum aspiration mechanical thrombectomy with Lightning Flash allows broader clinical application, enhanced procedural safety, and improved clinical outcomes for the treatment of acute and subacute iliofemoral and central deep venous thrombosis.
Article in Journal of vascular surgery cases and innovative techniques, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- May-Thurner syndrome disguised as pulmonary embolism: A case report.Journal of vascular surgery cases and innovative techniques · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We describe our experience with the 16F Lightning Flash vacuum aspiration mechanical thrombectomy system in 25 patients. All patients were treated in a single session with a mean estimated blood loss of 60 mL. Alteplase was not used in any patient in this series. Resolution of at least 50% thrombus or more at the end of the procedure on intravascular ultrasound examination was performed for all patients. Eight-eight percent of patients maintained venous patency at their most recent follow-up range, 8-26 months). No perioperative pulmonary embolism or device-related complications were observed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.