Design, fabrication, commissioning, and dosimetric verification of a GRID collimator for proton SFRT on a compact proton therapy machine.

Jufri Setianegara, Winter Green, Xiandong Zhao, Thomas R Mazur, Arash Darafsheh, Anthony J Apicelli, Shahed N Badiyan, Stephanie M Perkins, Tianyu Zhao, Michael T Prusator

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. A review on radiochromic film dosimetry in radiation therapy.Journal of applied clinical medical physics · 2025
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jufri SetianegaraDepartment of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Winter GreenDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Xiandong ZhaoDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Thomas R MazurDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Arash DarafshehDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Anthony J ApicelliDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Shahed N BadiyanDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Stephanie M PerkinsDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
Tianyu ZhaoDepartment of Radiation Oncology, University of South Florida, Tampa, Florida, USA.
Michael T PrusatorDepartment of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProton GRID radiotherapy (RT) is an extension of photon spatially fractionated radiation therapy (SFRT) techniques for bulky invasive tumors. It has been hypothesized that GRID RT improves the therapeutic ratio by minimizing normal tissue toxicities associated with treating bulky volumes while inducing abscopal radiobiologic effects. However, compact, synchrocyclotron-based proton therapy machines with large spot sizes pose unique technical challenges in implementing proton GRID RT. PURPOSE: The purpose of this work is to (a) design and model a collimating brass aperture within the RayStation treatment planning system (TPS), (b) validate the designed aperture by creating a commissioning plan and measuring the absolute and relative proton dose distributions delivered, and (c) perform a robustness analysis to determine the allowable mechanical tolerances and uncertainties during treatment delivery.

methodsA custom (27 × 21.5 × 5 cm

resultsExperimental measurements showed the best dosimetric agreements with the TPS calculations for optimization cylinder diameters of 10 mm with gamma passing rates of at least 97.9%. 1D absolute proton dose measurements with an ionization chamber showed agreement within 2.11% of TPS calculations once correcting for partial-volume averaging. Simulated mounting or setup errors within the TPS indicated a lateral positional requirement of ± 1.5 mm and a longitudinal snout positional requirement of ± 3 cm to achieve gamma passing rates of at least 90% (institutional standards).

conclusionWe have commissioned a brass collimator consisting of milled divergent apertures for clinical SFRT treatments via a proton GRID technique. This process included an assessment of dosimetric sensitivity of aperture positioning error, and also dosimetric evaluation of the aperture model as a brass support structure within the TPS. Future works entail the creation of clinical SFRT plans using different planning techniques and their respective dose comparisons.

Indexed as

Dose Fractionation, RadiationProton TherapyRadiometryEquipment DesignRadiotherapy DosageRadiotherapy Planning, Computer-AssistedcollimatorGRID radiotherapyproton therapyspatially fractionated radiation therapysynchrocyclotron

Identifiers

PMID40660954
PMCPMC12271000

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.