ArticleMedical physics2025
Early generation dynamic and static proton arc treatment planning algorithms assessment in oropharyngeal cancer patients.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Particle Arc Therapy in Cancer Radiotherapy: A Scoping Review of Feasibility and Dosimetric Evidence.Cancers · 2026Review
- Proton therapy in Spain: SEOR-SPROMP multidisciplinary recommendations developed through a RAND/UCLA consensus process.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2026Review
- Automated Planning for Bias-Free Validation of Discrete Proton Arc Therapy for Oropharyngeal Cancer.International journal of particle therapy · 2025Article
- Shoot-through layers in upright proton arcs unlock advantages in plan quality and range verification.Medical physics · 2025Article
- Early generation dynamic and static proton arc treatment planning algorithms assessment in oropharyngeal cancer patients.Medical physics · 2025Article
Corrections and comments
- Erratum issued
Authors and funding
16 authors.
Funding
Abstract
backgroundCompared with intensity modulated proton therapy (IMPT), proton arc treatment (PAT) employs an increased number of gantry angles, potentially reducing healthy tissues doses, especially for complex target geometries found in oropharyngeal cancer (OPC) treatment. PAT plans can be optimized with algorithms, based either on "static" gantry position or "dynamic" gantry movement during dose delivery. Recent results have shown target coverage may suffer more from inter-fraction patient anatomical- and setup changes In PAT than IMPT. PURPOSE: We assessed if PAT plans generated with one static and two dynamic PAT planning algorithms can improve expected plan toxicity, delivery time, and inter-fraction robustness compared to clinical volumetric modulated arc therapy (VMAT) and IMPT plans for OPC patients.
methodsSix OPC patients were included that qualified for proton therapy based on model-based selection, with IMPT plans superior to the VMAT plans in terms of toxicities. Static PAT plans were produced using an energy layer filtration (ELF) algorithm, and dynamic PAT plans were produced with two different methods: (1) Spot scanning Proton Arc (SPArc), and (2) Early Layer and Spot Assignment (ELSA). Two sets of PAT plans with about 360 or 240 energy layers and an additional ELF plan employing anterior oblique range shifted fields were produced. All proton plans were robustly optimized. Expected plan toxicity was determined using normal tissue complication probability (NTCP) models for dysphagia and xerostomia. A delivery time model was calibrated using experimental machine log-files and gantry dynamics from an IBA Proteus PLUS system (IBA Ltd, Belgium). Inter-fraction robustness was evaluated on a fraction-wise (on weekly repeated CT) and course-wise (accumulated over all weekly repeated CTs) basis.
resultsAll PAT strategies showed significantly (p-values < 0.05) reduced NTCPs for dysphagia and xerostomia grade ≥ 2 compared to IMPT and VMAT. Relative to VMAT, NTCP for xerostomia reduced by on average 4.0% in IMPT plans, 9.8% in ELF-, 9.6% in SPArc-, and 8.7% in ELSA PAT plans with 360 energy layers, and NTCP for dysphagia reduced by on average 9.6% in IMPT plans, 13.1% in ELF, 12.9% in SPArc, and 12.3% in ELSA PAT plans. Average clinical IMPT delivery time was 11.4 ± 2.1 min, while dynamic PAT delivery time was on average 7.6 ± 0.5 min for ELSA and 8.2 ± 0.5 min for SPArc plans with 360 energy layers and auto beam sequencing delivery for 360 energy layer 30 beam angle ELF plans was 9.9 ± 1.0 min. Reduction of energy layers to 240 resulted in limited NTCP increase, globally < 1%, and reduced delivery time by up to 3 min, where changes in delivery time and NTCP were largest in ELF plans. Fraction-wise target coverage was worse in the PAT plans compared to IMPT; however the course-wise coverage showed to be less impacted by inter-fraction changes. The addition of anterior oblique fields with range shifters markedly improved fraction- and course-wise target coverage for the ELF plans.
conclusionsThe tested static and dynamic PAT planning strategies showed similar significant reductions in NTCP compared to IMPT and VMAT. Estimated PAT delivery times were shorter compared to times for current delivery procedures of clinical IMPT plans. Dynamic PAT delivery is faster than static PAT. Fraction-wise robustness suffered more than course-wise robustness due to anatomical changes found in repeated CTs. Range shifters can be employed to improve PAT plan robustness.