ArticleMedical physics2025

Towards a more realistic anthropomorphic chest phantom using 3D-printed and cork-integrated components.

Joost F Hop, Ivan Dudurych, Thom R G Stams, Geertruida H de Bock, Rozemarijn Vliegenthart, Marcel J W Greuter

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Joost F HopDepartment of Radiology, University Medical Center Groningen, Groningen, the Netherlands.
Ivan DudurychDepartment of Radiology, University Medical Center Groningen, Groningen, the Netherlands.
Thom R G StamsDepartment of Radiology, University Medical Center Groningen, Groningen, the Netherlands.
Geertruida H de BockDepartment of Epidemiology, University Medical Center Groningen, Groningen, the Netherlands.
Rozemarijn VliegenthartDepartment of Radiology, University Medical Center Groningen, Groningen, the Netherlands.
Marcel J W GreuterDepartment of Radiology, University Medical Center Groningen, Groningen, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThorax phantoms for computed tomography (CT) imaging often lack realistic lung parenchyma and bronchovascular anatomy. To improve anatomical accuracy, 3D-printed chest phantoms have been developed as more realistic alternatives to existing models. PURPOSE: To evaluate whether an in-house developed anthropomorphic phantom insert realistically represents the anatomical structures and attenuation characteristics compared to the original phantom and human CT data.

methodsThe anthropomorphic chest phantom "Lungman" was modified by integrating a 3D-printed insert, cork-based lung parenchyma, and lung nodules. The phantom was scanned on a CT system and evaluated using qualitative and quantitative CT analyses, comparing attenuation values and histogram distributions to human CT data. Subjective radiologist assessments were conducted to compare anatomical realism between the modified and unmodified phantom.

resultsQualitative assessment of CT value distribution showed strong similarity between the modified phantom and human lung parenchyma, although the radiodensity characteristics of the 3D-printed bronchovascular insert still require further refinement. Quantitative analysis confirmed that the modified phantom's parenchymal attenuation (-854 Hounsfield unit [HU]) closely matched human lung parenchyma (-872 HU, p > 0.05), whereas the unmodified phantom showed lower attenuation (-997 HU, p < 0.05). However, the bronchovascular insert showed lower attenuation than human vasculature (-41 HU vs. 42 HU, p < 0.05). Radiologists rated the modified phantom higher for anatomical realism.

conclusionsThis study presents a modified, anthropomorphic thorax phantom that integrates realistic 3D-printed bronchial and vascular structures, lung parenchyma, and lung nodules.

Indexed as

Phantoms, ImagingPrinting, Three-DimensionalRadiography, ThoracicThoraxTomography, X-Ray ComputedHumansLung3D‐printinganthropomorphic thorax phantomcomputed tomographylung cancerpulmonary nodulesquality assurance

Identifiers

PMID40660862
PMCPMC12260776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.