ArticleJournal of applied clinical medical physics2025
Feasibility of a normoxic N-vinylpyrrolidone-based polymer gel (VIPET) dosimeter for three-dimensional proton beam measurements.
Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Feasibility of a normoxic N-vinylpyrrolidone-based polymer gel (VIPET) dosimeter for three-dimensional proton beam measurements.Journal of applied clinical medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundGel dosimeters enable three-dimensional dose measurement in x-ray and charged-particle therapies. A normoxic N-vinylpyrrolidone-based polymer gel (VIPET) dosimeter is expected to provide high-precision proton dose measurements. However, reports on the fundamental performance of VIPET gel dosimeters in proton beam measurement are limited, and the accuracy of position and dose measurements still needs to be determined. PURPOSE: We evaluated the accuracy of the VIPET gel dosimeter in proton beam measurement.
methodsProton beams of 190 MeV were delivered at dose rates of 2 and 8 Gy/min, and N-vinylpyrrolidone-based polymer gel dosimeters containing an inorganic salt as a sensitizer (iVIPET) were irradiated with a 10 × 10 cm
resultsA strong linear relationship was observed in the 0-30 Gy range. Dose uncertainties were in the range 1%-3%. Three sets of percentage depth dose measurements showed good agreement within 1.6%. Energy (LET) dependence led to measured peak doses being 23% lower than the treatment planning system (TPS) calculations. Proton energy effects in the plateau region were limited and dose rate effects were not recognized. Beam profiles in the axes parallel and perpendicular to the beam axis showed variations of approximately 1.2% and 1.3%, respectively, compared with the TPS calculations. The SPR was consistent with the TPS derived from CT values (1.03).
conclusionsThe VIPET dosimeter showed high reproducibility and uniformity in range and dose measurements of proton therapy beams without energy dependency in the plateau region or dose rate dependency in 2-8 Gy/min. The dosimeter also showed energy (LET) dependence comparable with that reported in previous studies.