Evidence map›Paper›PMID 40657525›Full record

ArticleIEEE journal of translational engineering in health and medicine2025

A Practical Sensor-to-Segment Calibration Method for Upper Limb Inertial Motion Capture in a Clinical Setting.

Mhairi McInnes, Dimitra Blana, Andrew Starkey, Edward K Chadwick

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mhairi McInnesSchool of EngineeringUniversity of Aberdeen Aberdeen AB24 3FX U.K.ORCID 0009-0003-1851-5344
Dimitra BlanaAberdeen Centre for Health Data ScienceUniversity of Aberdeen Aberdeen AB24 3FX U.K.ORCID 0000-0003-0488-6120
Andrew StarkeySchool of EngineeringUniversity of Aberdeen Aberdeen AB24 3FX U.K.ORCID 0000-0003-1797-8737
Edward K ChadwickSchool of EngineeringUniversity of Aberdeen Aberdeen AB24 3FX U.K.ORCID 0000-0003-0877-5110

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Inertial sensors have the potential to be a useful clinical tool because they can facilitate human motion capture outside the research setting. A major barrier to the widespread application of inertial motion capture is the lack of accepted calibration methods for ensuring accuracy, in particular the lack of a common convention for calculating the rotational offset of the sensors, known as sensor-to-segment calibration. The purpose of this study was to develop and test a sensor-to-segment calibration method for upper limb motion capture which is practical for clinical applications.We developed a calibration method which depends mainly on the estimation of joint axes from arbitrary elbow motion, and partially on the design of custom attachment mounts to achieve physical alignment. With twenty healthy participants, we used OpenSim's inertial sensor workflow to calculate joint kinematics, and evaluated the accuracy of the method through comparison with optical motion capture.We found the new calibration method resulted in upper limb kinematics with a median RMS error of 5-8°, and a median correlation coefficient of 0.977-0.987, which was significantly more accurate than a static pose calibration (p-value < 0.001).This work has demonstrated a method of calibration which is practical for clinical applications because it is quick to perform and does not depend on the subject's ability to perform specific movements, or on the operator's ability to carefully place sensors.Clinical Impact: The calibration method proposed in this work is a realistic option for the translation of inertial sensor technology into everyday clinical use.

Indexed as

Upper ExtremityAdultBiomechanical PhenomenaCalibrationFemaleHumansMaleMotion CaptureMovementYoung AdultClinical motion analysisIMUjoint axes estimationwearable sensors

Identifiers

PMID40657525
PMCPMC12250904

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.