Evidence map›Paper›PMID 40656919›Full record

Observational studyJNMA; journal of the Nepal Medical Association2025

Comparison of Fat Suppression Sequences T2 Weighted Two-Point Dixon and Short-Tau Inversion Recovery in Magnetic Resonance Imaging of Lumbar Spine: An Observational Study.

Umesh Khanal, Ramswarth Sah, Sushil Kumar Mahato, Shailendra Katwal, Ghanshyam Gurung

Abstract readObservational StudyComparative Study
In one paragraph

Observational study in JNMA; journal of the Nepal Medical Association, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Umesh KhanalDepartment of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj Medical Campus, Maharajgunj, Kathmandu, Nepal.
Ramswarth SahDepartment of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj Medical Campus, Maharajgunj, Kathmandu, Nepal.
Sushil Kumar MahatoDepartment of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj Medical Campus, Maharajgunj, Kathmandu, Nepal.
Shailendra KatwalDepartment of Radiology and Imaging, National Trauma Center, Kathmandu, Nepal.
Ghanshyam GurungDepartment of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj Medical Campus, Maharajgunj, Kathmandu, Nepal.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Magnetic Resonance Imaging is a common diagnostic tool used to evaluate various clinical conditions. Different fat suppression techniques such as Short Tau Inversion Recovery and Dixon are employed to enhance diagnostic accuracy. The choice of fat suppression sequence varies based on availability and performance. This study aimed to compare Contrast Ratio and Contrast-to-Noise Ratio of Short Tau Inversion Recovery and Dixon technique. Methods: This observational cross-section study was performed in the Department of Radiology from 8 September 2023 to 7 September 2024 after the approval by the Institutional Review Committee (Reference number: 151/080/081(6-11)E2). Using a complete census method during the study period, MRI-lumbar spines of 384 adult patients were included in the study. Signal intensity values of the lesion, adjacent normal tissue, and noise were recorded for calculation of Contrast Ratio and Contrast-to-Noise Ratio. Results: Among 384 cases, 191 (49.74%) were male and 193 (50.26%) were female with median age 46 (IQR: 35-60) years. The median value of contrast ratio and contrast-to-noise ratio were 0.31 (IQR: 0.14-0.50) and 8.74 (IQR: 3.82-15.50) respectively for STIR sequence while median value of contrast ratio and contrast-to-noise ratio were 0.44 (IQR: 0.19-0.74) and 11.95 (IQR: 5.38-23.18) respectively for Dixon sequence, higher than Short Tau Inversion Recovery. Conclusions: Contrast Ratio and Contrast to Noise Ratio were found higher and background noise lower for Dixon compared to Short Tau Inversion Recovery.

Indexed as

Lumbar VertebraeMagnetic Resonance ImagingAdipose TissueAdultCross-Sectional StudiesFemaleHumansMaleMiddle AgedSignal-To-Noise Ratiocontrastfatintensitynoisesignal

Identifiers

PMID40656919
PMCPMC12122274

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.