ArticleTurkish journal of chemistry2025
Highly sensitive and selective detection of KLK4 in human serum with a low-cost electrochemical biosensor.
Article in Turkish journal of chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
An ultrasensitive impedimetric immunosensor was fabricated using a poly(glycidyl methacrylate) (PGMA) polymer-covered indium tin oxide (ITO) platform for the quantification of kallikrein 4 (KLK4), an important prostate cancer biomarker. PGMA had suitable biocompatibility and nontoxicity for loading of antiKLK4 antibodies on the ITO substrate surface. Anti-KLK4 biomolecules were directly attached to the PGMA-covered electrode surface via epoxy groups of the PGMA polymer. The preparation method for the PGMA matrix-modified electrode was simple and inexpensive. The proposed biosensor immobilization layers coated on the ITO electrode were characterized with electrochemical techniques. The experimental parameters that affect biosensor response were optimized, and the suggested sensor showed a linear response from 0.04 pg/mL to 8 pg/mL with a low detection limit (LOD) of 12.21 fg/mL. Moreover, it had acceptable stability, reproducibility, and repeatability. Additionally, the disposable biosensor offered excellent reliability and accuracy in KLK4 analysis, suggesting that it could be used as an alternative technique in clinical diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.