Evidence map›Paper›PMID 40655788›Full record

ReviewJournal of pharmacy & bioallied sciences2025

Comparative Evaluation of Stress at the Implant Bone Interface Between Short Implants and Long Implants Using BioHPP Abutment- An

C Thamarai, Annapoorni Hariharan, K Thanya, Aaron G Baby, A R Saishree, B Devi Parameswari, D Narmadha

Abstract readReview
In one paragraph

Review in Journal of pharmacy & bioallied sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

C ThamaraiDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.
Annapoorni HariharanDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.
K ThanyaDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.
Aaron G BabyDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.
A R SaishreeDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.
B Devi ParameswariDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.
D NarmadhaDepartment of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: To compare and evaluate the stress at the implant-bone interface between short implants and long implants using BioHPP abutment. Settings and Design: Materials and Methodology: 10 PMMA mandibular models with implants, used in the study, were divided into 2 groups, Group L-10 implants (diameter-4.5 mm; length-14 mm); Group S-10 implants (diameter-5 mm, and length-5.2 mm). BioHPP abutments were fixed over the implant fixtures in both the groups, and monolith crowns were cemented. The crowns were then loaded with an universal testing machine, and the resultant stress was recorded using a strainmeter. A comparative study is done between Groups L and S to evaluate the stress distribution at the implant-bone interface. Statistical Analysis Used: Descriptive statistics (mean and standard deviation) were used to analyze stress in both Group L and Group S. Normality was checked with the Shapiro-Wilk test, and variance equality was assessed using Levene's test. Intergroup comparisons were made using an unpaired Results: The stresses at the implant-bone interface between the Group L and Group S are statistically insignificant for all type of load application at various points of loading. Conclusion: Based on the results, it can be concluded that the use of long or short implants with BioHPP abutments and monolith crowns will not affect the stresses at the implant-bone interface.

Indexed as

BioHPP abutmentimplant–bone interfacemonolith crownshort implantstress distribution

Identifiers

PMID40655788
PMCPMC12244893

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.