ArticleJournal of experimental orthopaedics2025

Low frequency of radiolucent lines in 3D-printed porous-coated tibial cementless baseplate at 1-year follow-up.

Yoshinori Mikashima, Hitoshi Imamura, Koichiro Yano, Katsunori Ikari, Hiroshi Takagi, Ken Okazaki

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yoshinori MikashimaOume Knee Surgery Center, Takagi Hospital Ome Japan.ORCID https://orcid.org/0000-0002-4176-5531
Hitoshi ImamuraOume Knee Surgery Center, Takagi Hospital Ome Japan.
Koichiro YanoDepartment of Orthopaedics Tokyo Women's Medical University Shinjuku-ku Japan.
Katsunori IkariDepartment of Orthopaedics Tokyo Women's Medical University Shinjuku-ku Japan.
Hiroshi TakagiDepartment of Orthopaedics Tokyo Women's Medical University Adachi Medical Center Adahi-ku Japan.
Ken OkazakiDepartment of Orthopaedics Tokyo Women's Medical University Shinjuku-ku Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: A recently introduced 3D-printed porous-coated tibial baseplate (ATTUNE AFFIXIUM, DePuy Synthes) was hypothesised to yield radiographical and clinical results that are comparable to those of its cementless predecessor with sintered beaded porous coating (POROCOAT, DePuy Synthes). Methods: A consecutive series of total knee arthroplasties (TKAs) was performed by a single surgeon using a baseplate covered with either AFFIXIUM® 3D-printed porous coating or POROCOAT® sintered beaded porous coating. The presence of radiolucent lines (RLLs) and bone on-growth over the surface of the tibial baseplate were retrospectively reviewed at 1 week, 1, 2, 4, 6 months and 1 year postoperatively. The 2011 Knee Society Score, Forgotten Joint Score-12 (FJS-12), hip-knee-ankle (HKA) angle were also reviewed. One-to-one matching was performed for age, sex, body mass index and preoperative University of California, Los Angeles score. Fisher's exact test or independent Student's Results: Fifty AFFIXUM® and 50 POROCOAT® cementless TKAs were reviewed after 1:1 matching at 1 year postoperatively. RLLs appeared in 15 knees (30%) of POROCOAT® TKAs at 6 months postoperatively, whereas RLLs appeared in two knees (4%) of AFFIXIUM® TKAs (<0.01). RLLs in 6 of 15 POROCOAT TKAs (40%) and 1 of 2 AFFIXIUM TKAs (50%) disappeared 1 year postoperatively. Bone on-growth over the surface of the tibial baseplate was observed in the same way in both groups. There were no significant differences in the 2011 Knee Society Scores and Forgotten Joint Scores-12 between the cohorts, with no patients requiring revision surgery (not significant). Conclusion: A very low frequency of RLLs was observed on a newer 3D-printed porous-coated tibial baseplate design for TKA at 1-year follow-up. Level of Evidence: Level III, retrospective cohort study.

Indexed as

3D‐printed porous‐coatedcementlessradiolucent linestotal knee arthroplasty

Identifiers

PMID40655261
PMCPMC12255930

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.