ArticleJournal of applied clinical medical physics2025
Semi-automated hippocampal avoidance whole-brain radiotherapy planning.
Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Semi-automated hippocampal avoidance whole-brain radiotherapy planning.Journal of applied clinical medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHippocampal avoidance whole-brain radiotherapy (HA-WBRT) is designed to spare cognitive function by reducing radiation dose to the hippocampus during the treatment of brain metastases. Current manual planning methods can be time-consuming and may vary in quality, necessitating the development of automated approaches to streamline the process and ensure consistency. PURPOSE: To automate hippocampal avoidance whole-brain radiotherapy (HA-WBRT) planning.
methodsOur algorithm automatically contours organs-at-risk (OARs) and the hippocampal-avoidance brain target. The algorithm generates planning structures from given contours, utilizing preset beam parameters and dose constraints for optimization. If the dose constraints are unmet, "hotspot" contours will be created to improve dosimetry. The algorithm was written with RayStation's scripting feature and was compared with clinically approved manual HA-WBRT plans for 20 retrospective patients using target and OAR dose metrics, with statistical analysis performed using the Student's t-test. In the qualitative review, an experienced radiation oncologist blindly scored both the manual plans and autoplans for qualitative review. Lastly, IMRT QA was performed to determine the plans' deliverability.
resultsThe autoplans demonstrated a better target coverage with a more uniform dose. With a prescription dose of 3000 cGy, autoplans achieved higher D
conclusionsOur rule-based autoplanning algorithm produces high-quality plans that are comparable to those of manual planning, demonstrating autoplanning's potential to reduce HA-WBRT planning time while ensuring consistent plan quality.
Indexed as