ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2025

Assessment of contact force variability in the MAGiC catheter under different magnetic field strengths, vector orientations, and catheter extensions in robotic magnetic navigation.

Michal Orczykowski, Maciej Bak, Andrzej Glowniak, Krzysztof Kaczmarek, Piotr Urbanek, Robert Bodalski, Krzysztof Dubowski, Anna Jargielo, Pawel Derejko, Pawel Ptaszynski and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Michal Orczykowski *Arrhythmia Center, National Institute of Cardiology, Warsaw, Poland. mikeorczyk@gmail.com.
Maciej Bak *Arrhythmia Center, National Institute of Cardiology, Warsaw, Poland.
Andrzej GlowniakDepartment of Cardiology, Medical University of Lublin, Lublin, Poland.
Krzysztof KaczmarekDepartment of Cardiology, Medical University of Lodz, Lodz, Poland.
Piotr UrbanekArrhythmia Center, National Institute of Cardiology, Warsaw, Poland.
Robert BodalskiArrhythmia Center, National Institute of Cardiology, Warsaw, Poland.
Krzysztof DubowskiArrhythmia Center, National Institute of Cardiology, Warsaw, Poland.
Anna JargieloArrhythmia Center, National Institute of Cardiology, Warsaw, Poland.
Pawel DerejkoMedicover Hospital, Warsaw, Poland.
Pawel PtaszynskiDepartment of Cardiology, Medical University of Lodz, Lodz, Poland.
Lukasz SzumowskiArrhythmia Center, National Institute of Cardiology, Warsaw, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContact force (CF) in manually controlled catheters is crucial for forming an optimal lesion. There is lack of published data on CF values of MAGiC catheter (Stereotaxis, St. Louis, MO, USA) in magnetic field.

methodsWe conducted a total of 2500 CF measurements using the Robotic Magnetic Navigation (RMN) system (Stereotaxis, St. Louis, MO, USA), a magnetic-guided 8,5 Fr RF ablation catheter MAGiC (Stereotaxis, St. Louis, MO, USA) inserted through a long sheath, and a precision jewelry scale (IKEME, Guangdong, CN). We analyzed the impact on the obtained CF values of five different magnetic field vectors (transverse, caudal, cranial, sagittal, and anterior), two field strengths (0.1 T and 0.08 T), and five catheter extension configurations from the long sheath. Additionally, we compared the CF values of the MAGiC catheter and the THERMOCOOL® RMT Catheter (Biosense Webster, Irvine, CA, USA) using two models.

resultsThe measured CF values of MAGiC catheter ranged from 5.62 to 21.61 g (0.1 T) and 3.63 to 20.74 g (0.08 T) and varied depending on the vectors. CF was higher at 0.1 T than 0.08 T, with values ranging from 9.32 to 21.61 g (0.1 T) and 8.71 to 20.74 g (0.08 T). In Model I comparison of MAGiC and THERMOCOOL® RMT, the MAGiC catheter had significantly higher CF (p < 0.001) in 28/30 measurements scenarios. In Model II, CF was higher in 24/30 scenarios (p < 0.001).

conclusionThe MAGiC catheter provides consistently optimal CF values across multiple orientations and catheter extension models, outperforming the THERMOCOOL® RMT Catheter in most scenarios.

Indexed as

AblationContact forceMagnetic fieldRadiofrequency catheterRobotic magnetic navigation