Evidence map›Paper›PMID 40652247›Full record

SynthesisCritical care (London, England)2025

Cardiac output monitors in septic shock: do they deliver what matters? A systematic review and meta-analysis.

Raquel Lamarche-Fontaneto, Lee Oud, Kayln D Howell, Simran A Ganeriwal, Gaurav U Manek, Mary C Schleicher, Jihad Mallat, Maurizio Cecconi, Abhijit Duggal, Matthew T Siuba

Abstract readSystematic ReviewMeta-Analysis
In one paragraph

Synthesis in Critical care (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Not all pulse contour algorithms are created equal.Critical care (London, England) · 2025
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Raquel Lamarche-FontanetoDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA. lamarcr@ccf.org.
Lee OudDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Kayln D HowellDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Simran A GaneriwalDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Gaurav U ManekDepartment of Pulmonary and Critical Care Medicine, MedStar Southern Maryland Hospital Center, Clinton, MD, USA.
Mary C SchleicherCleveland Clinic Floyd D. Loop Alumni Library, Cleveland, OH, USA.
Jihad MallatDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic Abu Dhabi, Abu Dhabi, United Arab Emirates.
Maurizio CecconiDepartment of Anesthesia and Intensive Care, IRCCS Humanitas Research Hospital, Milan, Italy.
Abhijit DuggalDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Matthew T SiubaDepartment of Pulmonary and Critical Care Medicine, Integrated Hospital Care Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To evaluate the interchangeability of cardiac output (CO) monitoring devices compared to reference methods in adult ICU patients with septic shock, we systematically searched electronic databases through January 2025 for prospective studies comparing CO monitors with pulmonary artery catheter (PAC), transpulmonary thermodilution (TPTD), or echocardiography. Eligible studies included Bland-Altman analysis and, when available, trending assessment via polar or 4-quadrant plots, precision, and time response.  Agreement was defined as percentage error (PE) < 30%, and acceptable trending as concordance ≥ 90%. Pooled bias, limits of agreement (LoA), and PE were calculated using the Sidik-Jonkman random-effects model. Twenty-six studies were included, yielding 37 unique device-reference datasets and encompassing 1,323 patients. PAC was the most common reference (18 datasets), followed by TPTD (16) and echocardiography (3). The pooled bias was 0.15 L min⁻¹ with LoA of ± 3.45 L min⁻¹ and pooled PE of 49%. Calibrated pulse contour analysis (PCA) showed the best agreement (PE 25%), whereas uncalibrated PCA, thoracic electrical bioimpedance, and bioreactance demonstrated poor agreement (PE ≥ 52%). Heterogeneity for mean bias was high across all subgroups (I² >80%). Of 15 datasets reporting trending, only three achieved concordance ≥ 90%. Most CO monitors demonstrate poor agreement with reference methods in septic shock. However, their true clinical utility remains unclear, as usual validation frameworks-centered on Bland-Altman analysis-overlook metrics that matter most to intensivists. Precision, time response, and trending ability are critical for real-time decision-making but were rarely assessed. Future studies must incorporate these parameters to meaningfully evaluate device performance at the bedside. PROSPERO registration: CRD42024509384.

Indexed as

Cardiac OutputShock, SepticCatheterization, Swan-GanzHumansIntensive Care UnitsMonitoring, PhysiologicProspective StudiesThermodilutionCardiac outputHemodynamic monitoringMeta-analysisPulmonary artery catheterSeptic shock

Identifiers

PMID40652247
PMCPMC12255103

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.