SynthesisCritical care (London, England)2025
Cardiac output monitors in septic shock: do they deliver what matters? A systematic review and meta-analysis.
Synthesis in Critical care (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Automated hemodynamic resuscitation system for computer-controlled norepinephrine, vasopressin, and fluid therapy in endotoxin-induced shock: a feasibility and physiological proof-of-concept study.Intensive care medicine experimental · 2026Article
- Clinical criteria for the definition of refractory septic shock: a joint Delphi consensus from the Society of Critical Care Medicine (SCCM) and European Society of Intensive Care Medicine (ESICM).Intensive care medicine · 2026Article
- Automatic monitoring of single-wall MAPSE by transesophageal echocardiography for tracking global left ventricular function irrespective of regional hypokinesia: a secondary analysis.Intensive care medicine experimental · 2026Article
- Hemodynamic monitoring: basic principles in operation room and intensive care unit.Journal of clinical monitoring and computing · 2026Review
- Less-Invasive Hemodynamic and Tissue Perfusion Monitoring in Sepsis and Septic Shock: A Narrative Review.Journal of clinical medicine · 2026Review
- Invasive hemodynamic monitoring-guided resuscitation improves survival in shock: A systematic review and meta-analysis.Annals of intensive care · 2026Review
- Agreement and trending ability between non-invasive and invasive hemodynamic monitoring during cesarean section under spinal anesthesia: a prospective observational study.Frontiers in medicine · 2026Article
- Moving-average processing enables accurate quantification of time delay and compares the trending ability of cardiac output monitors with different response times.BMC biomedical engineering · 2025Article
- Not all pulse contour algorithms are created equal.Critical care (London, England) · 2025Article
Corrections and comments
- Commented on by
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To evaluate the interchangeability of cardiac output (CO) monitoring devices compared to reference methods in adult ICU patients with septic shock, we systematically searched electronic databases through January 2025 for prospective studies comparing CO monitors with pulmonary artery catheter (PAC), transpulmonary thermodilution (TPTD), or echocardiography. Eligible studies included Bland-Altman analysis and, when available, trending assessment via polar or 4-quadrant plots, precision, and time response. Agreement was defined as percentage error (PE) < 30%, and acceptable trending as concordance ≥ 90%. Pooled bias, limits of agreement (LoA), and PE were calculated using the Sidik-Jonkman random-effects model. Twenty-six studies were included, yielding 37 unique device-reference datasets and encompassing 1,323 patients. PAC was the most common reference (18 datasets), followed by TPTD (16) and echocardiography (3). The pooled bias was 0.15 L min⁻¹ with LoA of ± 3.45 L min⁻¹ and pooled PE of 49%. Calibrated pulse contour analysis (PCA) showed the best agreement (PE 25%), whereas uncalibrated PCA, thoracic electrical bioimpedance, and bioreactance demonstrated poor agreement (PE ≥ 52%). Heterogeneity for mean bias was high across all subgroups (I² >80%). Of 15 datasets reporting trending, only three achieved concordance ≥ 90%. Most CO monitors demonstrate poor agreement with reference methods in septic shock. However, their true clinical utility remains unclear, as usual validation frameworks-centered on Bland-Altman analysis-overlook metrics that matter most to intensivists. Precision, time response, and trending ability are critical for real-time decision-making but were rarely assessed. Future studies must incorporate these parameters to meaningfully evaluate device performance at the bedside. PROSPERO registration: CRD42024509384.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.