Evidence map›Paper›PMID 40650771›Full record

ArticleArchives of orthopaedic and trauma surgery2025

Comparative biomechanical evaluation of the U-shaped lumbopelvic stabilization technique in treating unstable sacral fractures.

Dennis Nebel, Manuel Ferle, Thorben Schulz, Bastian Welke, Tilman Graulich, Sebastian Decker

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dennis NebelLaboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, DIAKOVERE Annastift, Anna-von-Borries Str. 1-7, 30625, Hanover, Germany. nebel.dennis@mh-hannover.de.
Manuel FerleDepartment of Ergonomics, Technical University of Munich, 85748, Garching, Munich, Germany.
Thorben SchulzLaboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, DIAKOVERE Annastift, Anna-von-Borries Str. 1-7, 30625, Hanover, Germany.
Bastian WelkeLaboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, DIAKOVERE Annastift, Anna-von-Borries Str. 1-7, 30625, Hanover, Germany.
Tilman GraulichDepartment of Trauma Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.
Sebastian DeckerDepartment of Trauma Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hanover, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionLumbopelvic fixation is commonly employed to stabilize unstable sacral fractures, particularly U-shaped (US) fractures, which may result in spinopelvic dissociation-leading to significant pain, deformity, and neurological deficits. Due to its superior biomechanical properties, lumbopelvic stabilization (LPS) has become the preferred method for managing such injuries. We aimed to compare the biomechanical stability of US-LPS with conventional LPS and bilateral iliosacral screw (ISS) fixation. MATERIALS AND

methodsSix human cadaveric pelvic specimens were subjected to axial (750 N) and torsional (8 Nm) loading using a material testing machine (MTM). Seven configurations of LPS were evaluated. The range of motion (ROM) between three anatomical bony segments-the third lumbar vertebral body (LBV3), the first sacral vertebral body (SVB1), and the Crista Iliaca (CI)-was analyzed using an optical tracking system. Measurements included craniocaudal translation and anterior-posterior tilt under axial loading and internal-external rotation under torsional loading. Stiffness was calculated using force-displacement curves obtained via the MTM's integrated load cells and displacement transducers.

resultsBoth LPS and US-LPS configurations demonstrated reduced ROM and increased stiffness compared to ISS fixation under axial and torsional loading. US-LPS exhibited marginally greater stiffness than standard LPS. The use of additional cross-connectors in both LPS groups had minimal to no measurable impact on ROM or overall stability.

conclusionsUS-LPS offers slightly enhanced biomechanical stability over conventional LPS in the fixation of unstable US sacral fractures. In contrast, standalone ISS fixation did not improve stability compared to the unfixed condition in this cadaveric model.

Indexed as

Fracture Fixation, InternalSacrumSpinal FracturesAgedBiomechanical PhenomenaBone ScrewsCadaverFemaleHumansMaleMiddle AgedRange of Motion, ArticularIn vitro biomechanicsLumbopelvic stabilizationSacral fractureSurgical technique

Identifiers

PMID40650771
PMCPMC12255570

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.