Biomechanical comparison of cemented versus cementless fixation in intraoperative femoral fractures during total hip arthroplasty.

Ryunosuke Watanabe, Tomofumi Nishino, Tomohiro Yoshizawa, Fumi Hirose, Shota Yasunaga, Koshiro Shimasaki, Hajime Mishima

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ryunosuke WatanabeDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan. ryuwatanabe@tsukuba-seikei.jp.
Tomofumi NishinoDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Tomohiro YoshizawaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Fumi HiroseDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Shota YasunagaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Koshiro ShimasakiDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.
Hajime MishimaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIntraoperative periprosthetic femoral fractures (IPFF) are serious complications of total hip arthroplasty (THA) that occur more frequently with cementless stems than with cemented stems. Although cerclage wiring is commonly used to stabilize IPFFs, the biomechanical effects of subsequent stem fixation methods remain unclear. This study aimed to compare the biomechanical stability of cemented and cementless stems following cerclage wire fixation in an experimental IPFF model. MATERIALS AND

methodsSix fourth-generation composite femurs with simulated Vancouver A2-type fractures were stabilized using a single 1.8 mm cerclage wire. Identical stem designs of polished cemented stems and fully hydroxyapatite-coated cementless stems were implanted in three specimens of each group. After applying a vertical axial load of 2000 N, an additional 40° of internal rotation was imposed. The primary outcome was the maximum torque at the time of fracture. Secondary outcomes included the maximum internal rotation angle, construct stiffness (calculated from force-displacement curves above 1500 N), and peak strain at three positions on the cerclage wire, measured using strain gauges.

resultsThe maximum torque was significantly higher in the cemented group compared to the cementless group (160.8 ± 24.9 vs. 89.1 ± 18.0 N·m, p = 0.016). Although the differences in stiffness and internal rotation angle were not statistically significant, both trended higher in the cemented group. The peak strain was consistently lower in the cemented group, with a significant difference at the medial side of the fracture line (p = 0.011, Cohen's d = - 3.64).

conclusionsCemented stems demonstrated superior biomechanical stability following cerclage wire fixation in the IPFF model, likely because of improved stress distribution via the cement mantle. Therefore, cemented fixation may be a favorable option for managing IPFF during THA.

Indexed as

Bone CementsFemoral FracturesFemurFracture Fixation, InternalPeriprosthetic FracturesArthroplasty, Replacement, HipBiomechanical PhenomenaBone WiresHip ProsthesisHumansIntraoperative ComplicationsModels, AnatomicTorqueTreatment OutcomeBone CementsBiomechanical testingCemented stemCementless stemCerclage wiringIntraoperative periprosthetic femoral fracturesTotal hip arthroplasty

Identifiers

PMID40650738
PMCPMC12255567

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.