Evidence map›Paper›PMID 40648424›Full record

ArticleSensors (Basel, Switzerland)2025

Real-Time Hand Gesture Recognition in Clinical Settings: A Low-Power FMCW Radar Integrated Sensor System with Multiple Feature Fusion.

Haili Wang, Muye Zhang, Linghao Zhang, Xiaoxiao Zhu, Qixin Cao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Haili WangThe State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-0519-3919
Muye ZhangSJTU Paris Elite Institute of Technology, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0001-2613-0060
Linghao ZhangSchool of Computer Science, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0004-6023-5132
Xiaoxiao ZhuStudent Innovation Center, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-7086-4256
Qixin CaoThe State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0001-5462-9857

Funding

National Key R&D Program of China 2019YFC1711801
6 · The paper itself

Abstract

Robust and efficient contactless human-machine interaction is critical for integrated sensor systems in clinical settings, demanding low-power solutions adaptable to edge computing platforms. This paper presents a real-time hand gesture recognition system using a low-power Frequency-Modulated Continuous Wave (FMCW) radar sensor, featuring a novel Multiple Feature Fusion (MFF) framework optimized for deployment on edge devices. The proposed system integrates velocity profiles, angular variations, and spatial-temporal features through a dual-stage processing architecture: an adaptive energy thresholding detector segments gestures, followed by an attention-enhanced neural classifier. Innovations include dynamic clutter suppression and multi-path cancellation optimized for complex clinical environments. Experimental validation demonstrates high performance, achieving 98% detection recall and 93.87% classification accuracy under LOSO cross-validation. On embedded hardware, the system processes at 28 FPS, showing higher robustness against environmental noise and lower computational overhead compared with existing methods. This low-power, edge-based solution is highly suitable for applications like sterile medical control and patient monitoring, advancing contactless interaction in healthcare by addressing efficiency and robustness challenges in radar sensing for edge computing.

Indexed as

GesturesHandRadarAlgorithmsHumansPattern Recognition, Automatedclinical edge computingdeep learninghand gesture recognitionIoTmedical sensor systemsmillimeter-wave radarmultiple feature fusionreal-time

Identifiers

PMID40648424
PMCPMC12252275

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.