Technical Validation of a Training Workstation for Magnet-Based Ultrasound Guidance of Fine-Needle Punctures.

Christian Kühnel, Martin Freesmeyer, Falk Gühne, Leonie Schreiber, Steffen Schrott, Reno Popp, Philipp Seifert

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Christian KühnelClinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.ORCID 0000-0003-3307-1772
Martin FreesmeyerClinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.ORCID 0000-0002-6462-3851
Falk GühneClinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.
Leonie SchreiberClinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.
Steffen SchrottClinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.
Reno PoppeZono AG, 07743 Jena, Germany.
Philipp SeifertClinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.ORCID 0000-0002-3447-4971

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It has been demonstrated that needle guidance systems can enhance the precision and safety of ultrasound-guided punctures in human medicine. Systems that permit the utilization of commercially available standard needles, instead of those that necessitate the acquisition of costly, proprietary needles, are of particular interest. The objective of this phantom study is to evaluate the reliability and accuracy of magnet-based ultrasound needle guidance systems, which superimpose the position of the needle tip and a predictive trajectory line on the live ultrasound image. We conducted fine-needle aspiration cytology of thyroid nodules. The needles utilized in these procedures are of a slender gauge (21-27G), with lengths ranging from 40 to 80 mm. A dedicated training workstation with integrated software-based analyses of the movement of the needle tip was utilized in 240 standardized phantom punctures (angle: 45°; target depth: 20 mm). No system failures occurred, and the target achieved its aim in all cases. The analysis of the software revealed stable procedural parameters with minor relative deviations from the predefined reference values regarding the distance of needle tip movement (-4.2% to +6.7%), needle tilt (-6.4% to +9.6%), and penetration depth (-7.5% to +4.5%). These deviations appeared to increase with the use of thin needles and, to a lesser extent, long needles. They are attributed to the slight bending of the needle inside the (phantom) tissue. The training workstation we employed is thus suitable for use in educational settings. Nevertheless, in intricate clinical puncture scenarios-for instance, in the case of unfavorable localized small lesions near critical anatomical structures, particularly those involving thin needles-caution is advised, and the system should not be relied upon exclusively.

Indexed as

MagnetsBiopsy, Fine-NeedleHumansNeedlesPhantoms, ImagingPuncturesSoftwareUltrasonographyaugmented realityneedle puncturetraining workstationultrasound guided

Identifiers

PMID40648356
PMCPMC12251687

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.