Evidence map›Paper›PMID 40648335›Full record

ArticleSensors (Basel, Switzerland)2025

Key Vital Signs Monitor Based on MIMO Radar.

Michael Gottinger, Nicola Notari, Samuel Dutler, Samuel Kranz, Robin Vetsch, Tindaro Pittorino, Christoph Würsch, Guido Piai

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Michael GottingerInstitute for Electronics, Sensorics and Actorics (ESA), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.ORCID 0000-0003-1726-4996
Nicola NotariInstitute for Computational Engineering (ICE), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.ORCID 0009-0000-7072-0095
Samuel DutlerInstitute for Computational Engineering (ICE), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.
Samuel KranzInstitute for Electronics, Sensorics and Actorics (ESA), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.ORCID 0009-0006-6766-6458
Robin VetschInstitute for Computational Engineering (ICE), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.
Tindaro PittorinoInstitute for Electronics, Sensorics and Actorics (ESA), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.ORCID 0009-0005-7548-1130
Christoph WürschInstitute for Computational Engineering (ICE), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.ORCID 0000-0002-1337-3477
Guido PiaiInstitute for Electronics, Sensorics and Actorics (ESA), Ostschweizer Fachhochschule, 9470 Buchs, Switzerland.ORCID 0009-0002-6549-1931

Funding

Innosuisse - Swiss Innovation Agency 44973.1 IP-ENG
6 · The paper itself

Abstract

State-of-the-art radar systems for the contactless monitoring of vital signs and respiratory diseases are typically based on single-channel continuous wave (CW) technology. This technique allows precise measurements of respiration patterns, periods of movement, and heart rate. Major practical problems arise as CW systems suffer from signal cancellation due to destructive interference, limited overall functionality, and a possibility of low signal quality over longer periods. This work introduces a sophisticated multiple-input multiple-output (MIMO) solution that captures a radar image to estimate the sleep pose and position of a person (first step) and determine key vital parameters (second step). The first step is enabled by processing radar data with a forked convolutional neural network, which is trained with reference data captured by a time-of-flight depth camera. Key vital parameters that can be measured in the second step are respiration rate, asynchronous respiratory movement of chest and abdomen and limb movements. The developed algorithms were tested through experiments. The achieved mean absolute error (MAE) for the locations of the xiphoid and navel was less than 5 cm and the categorical accuracy of pose classification and limb movement detection was better than 90% and 98.6%, respectively. The MAE of the breathing rate was measured between 0.06 and 0.8 cycles per minute.

Indexed as

RadarVital SignsAlgorithmsHeart RateHumansMonitoring, PhysiologicMovementNeural Networks, ComputerRespirationRespiratory RateSignal Processing, Computer-Assistedcomputer-aided diagnosisconvolutional neural networksdisplacement measurementsmachine learningMIMO radarpatient monitoringsleep apnea

Identifiers

PMID40648335
PMCPMC12251826

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked