Evidence map›Paper›PMID 40648152›Full record

ArticleSensors (Basel, Switzerland)2025

Fluxgate Magnetometers Based on New Physical Principles.

Ivan V Bryakin, Igor V Bochkarev, Vadim R Khramshin, Vadim R Gasiyarov, Ivan N Erdakov

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ivan V BryakinLaboratory of Information and Measuring Systems of the Institute of Mechanical Engineering, Automation and Geomechanics, National Academy of Sciences of the Kyrgyz Republic, Bishkek 720010, Kyrgyzstan.
Igor V BochkarevDepartment of Electromechanics, Kyrgyz State Technical University Named after I. Razzakov, Bishkek 720010, Kyrgyzstan.ORCID 0000-0002-9873-9203
Vadim R KhramshinPower Engineering and Automated Systems Institute, Nosov Magnitogorsk State Technical University, 455000 Magnitogorsk, Russia.ORCID 0000-0003-0972-2803
Vadim R GasiyarovDepartment of Automation and Control, Moscow Polytechnic University, 107023 Moscow, Russia.ORCID 0000-0001-9635-4716
Ivan N ErdakovDepartment of Metal Forming, South Ural State University, 454080 Chelyabinsk, Russia.ORCID 0000-0003-2005-4439

Funding

Moscow Polytechnic University This work was financially supported by the Moscow Polytechnic University within the frame-work of the grant named after Pyotr Kapitsa
6 · The paper itself

Abstract

This article considers a fluxgate magnetometer (FM) that operates based on a new physical principle. The authors analyze how the alternating electric charge potential of a cylindrical metal electrode impacts the structure of a cylindrical permanent magnet made of composite-conducting ferrite. They demonstrate that this impact and permanent magnet structure initiate the emergence of polarons with oscillating magnetism. This causes significant changes in the entropy of indirect exchange and the related sublattice magnetism fluctuations that ultimately result in the generation of circularly polarized spin waves at the spin wave resonance frequency that are channeled and evolve in dielectric ferrite waveguides of the FM. It is demonstrated that these moving spin waves have an electrodynamic impact on the measuring FM coils on the macro-level and perform parametric modulation of the magnetic permeability of the waveguide material. This results in the respective variations of the changeable magnetic field, which is also registered by the measuring FM coils. The authors considered a generalized flow of the physical processes in the FM to obtain a detailed representation of the operating functions of the FM. The presented experimental results for the proposed FM in the field meter mode confirm its operating parameters (±40 μT-measurement range, 0.5 nT-detection threshold). The usage of a cylindrical metal electrode as a source of exciting electrical change instead of a conventional multiturn excitation coil can significantly reduce temperature drift, simplify production technology, and reduce the unit weight and size.

Indexed as

cut cylindrical metal electrodeferrite rod waveguidefluxgate magnetometerHelmholtz coilspermanent composite-conducting ferrite magnetpolaron harmonic oscillatorspin oscillationsspin wave resonance

Identifiers

PMID40648152
PMCPMC12252027

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.