ArticleSensors (Basel, Switzerland)2025

Accuracy Testing of Torque Limit Determination Algorithm Intended for Smart Bone Screwdrivers.

Jack A Wilkie, Alberto Battistel, Paul D Docherty, Niklaus F Friederich, Georg Rauter, Knut Möller

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jack A WilkieInstitute of Technical Medicine, Hochschule Furtwangen University, Jakob-Kienzle-Strasse 17, 78054 Schwenningen, Germany.ORCID 0000-0002-0163-1133
Alberto BattistelInstitute of Technical Medicine, Hochschule Furtwangen University, Jakob-Kienzle-Strasse 17, 78054 Schwenningen, Germany.ORCID 0000-0002-6371-3580
Paul D DochertyCenter for Bioengineering, Department of Mechanical Engineering, University of Canterbury, 69 Creyke Road, Christchurch 8041, New Zealand.ORCID 0000-0003-1661-2573
Niklaus F FriederichDepartment of Biomedical Engineering, University of Basel, Hegenheimermattweg 167B/C, 4123 Allschwil, Switzerland.ORCID 0000-0002-9266-7472
Georg RauterDepartment of Biomedical Engineering, University of Basel, Hegenheimermattweg 167B/C, 4123 Allschwil, Switzerland.ORCID 0000-0001-9089-8181
Knut MöllerInstitute of Technical Medicine, Hochschule Furtwangen University, Jakob-Kienzle-Strasse 17, 78054 Schwenningen, Germany.ORCID 0000-0003-4709-3817

Funding

Federal Ministry of Education and Research 13FH5E02IA and 13FH5I05IA
6 · The paper itself

Abstract

Bone screws are used in orthopaedic surgery for fracture fixation. Correctly torquing the screws is important for fixation quality. Over-tightening may strip the threads, while under-tightening may result in loosening over time. This paper focuses on testing an approach where strength is estimated using screw insertion data from torque and rotation sensors, and stripping torque is predicted based on this strength. A common type of bone screw was inserted until stripping 10 times each into 8 types of polyurethane surrogate for bone. The torque-rotation data from the insertion was used to identify the material strength and estimate the stripping torque and compared with the experimental maximum torque. A good relationship was found between the estimated/predicted and true stripping torques (r = 0.926, 95% confidence interval (C.I.) [0.886, 0.952]), with a mean error of 18%. Additionally, the intermediate identified strength values were found to be highly correlated with the data-sheet values for the materials (r = 0.977, 95% C.I. [0.964, 0.985]). These outcomes demonstrate the viability and significance of this concept in general, although more development and testing is required for broad clinical applicability; such tests would be extended for more types of bone screws and use a large set of human bone samples to better reflect the natural variability.

Indexed as

AlgorithmsBone ScrewsHumansMaterials TestingTorquebone screwparameter identificationsmart screwdrivertorque control

Identifiers

PMID40648122
PMCPMC12252061

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked