What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Bone screws are used in orthopaedic surgery for fracture fixation. Correctly torquing the screws is important for fixation quality. Over-tightening may strip the threads, while under-tightening may result in loosening over time. This paper focuses on testing an approach where strength is estimated using screw insertion data from torque and rotation sensors, and stripping torque is predicted based on this strength. A common type of bone screw was inserted until stripping 10 times each into 8 types of polyurethane surrogate for bone. The torque-rotation data from the insertion was used to identify the material strength and estimate the stripping torque and compared with the experimental maximum torque. A good relationship was found between the estimated/predicted and true stripping torques (r = 0.926, 95% confidence interval (C.I.) [0.886, 0.952]), with a mean error of 18%. Additionally, the intermediate identified strength values were found to be highly correlated with the data-sheet values for the materials (r = 0.977, 95% C.I. [0.964, 0.985]). These outcomes demonstrate the viability and significance of this concept in general, although more development and testing is required for broad clinical applicability; such tests would be extended for more types of bone screws and use a large set of human bone samples to better reflect the natural variability.