Evidence map›Paper›PMID 40646244›Full record

ArticleEye (London, England)2025

Advancing AMD screening with an offline, AI-powered smartphone-based fundus camera: A prospective, real-world clinical validation.

Kalpa Negiloni, Prabu Baskaran, Divya Parthasarathy Rao, Aditya Maitray, Florian M Savoy, Shruthi Suresh, Maanasi Mahalingam, M J Vighnesh, Anand Rajendran

Abstract readValidation Study
In one paragraph

Article in Eye (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kalpa Negiloni *Remidio Innovative Solutions Pvt Ltd, Bengaluru, India. kalpa.n@remidio.com.ORCID http://orcid.org/0000-0002-4768-066X
Prabu Baskaran *Aravind Eye Hospital, Chennai, India.
Divya Parthasarathy RaoRemidio Innovative Solutions Inc, Glen Allen, VA, USA.
Aditya MaitrayAravind Eye Hospital, Chennai, India.ORCID http://orcid.org/0000-0002-7569-687X
Florian M SavoyMedios Technologies, Remidio Innovative Solutions Pte Ltd, Singapore, Singapore.ORCID http://orcid.org/0000-0001-8093-6228
Shruthi SureshAravind Eye Hospital, Chennai, India.
Maanasi MahalingamAravind Eye Hospital, Chennai, India.
M J VighneshRemidio Innovative Solutions Pvt Ltd, Bengaluru, India.
Anand RajendranAravind Eye Hospital, Chennai, India.ORCID http://orcid.org/0000-0002-8678-5325

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study evaluated a novel offline, AI-driven age-related macular degeneration (AMD) screening algorithm against fundus image-only grading and the standard of care (combined Spectral Domain-Optical Coherence Tomography (SD-OCT) and fundus image grading).

methodsConducted prospectively at a South Asian tertiary eye hospital, this study utilized a validated smartphone-based non-mydriatic fundus camera to capture macula-centred images. The Medios AI's ability to detect referable AMD was compared to a reference standard image grading, using fundus images from the Zeiss Clarus 700 table-top camera and SD-OCT line scan across fovea. Three retina specialists provided blinded AMD diagnoses based on: (1) Zeiss Clarus 700 fundus images alone, and (2) combined SD-OCT and fundus images (standard of care). Referable AMD was defined as intermediate or advanced AMD.

resultsAmong 984 eyes from 492 patients (mean age 61.8 ± 9.9 years), 52% had referable AMD. Inter-grader agreement was strong, with Cohen's Kappa scores of 0.81-0.84. The Medios AI's sensitivity and specificity for detecting referable AMD against fundus-only grading (n = 492) were 88.48% (95% CI: 84.04-92.03%) and 87% (95% CI: 81.86-91.11%), respectively. Against combined grading (n = 489), AI sensitivity was 90.62% (95% CI: 86.37-93.90%), and specificity was 85.41% (95% CI: 80.21-89.68%). False negatives were primarily intermediate AMD (71%), while 59% of false positives were early AMD.

conclusionThe novel, automated, offline AMD AI integrated on a smartphone fundus camera demonstrated robust performance in identifying referable forms of AMD, supporting its potential as an affordable and accessible screening solution.

Indexed as

Artificial IntelligenceDiagnostic Techniques, OphthalmologicalMacular DegenerationPhotographySmartphoneAgedAlgorithmsFemaleFundus OculiHumansMaleMiddle AgedProspective StudiesReproducibility of ResultsSensitivity and SpecificityTomography, Optical Coherence

Identifiers

PMID40646244
PMCPMC12402149

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.