Evidence map›Paper›PMID 40646064›Full record

ArticleScientific reports2025

Low-dose computed tomography image denoising using pixel level non-local self-similarity prior with non-local means for healthcare informatics.

Dawa Chyophel Lepcha, Bhawna Goyal, Ayush Dogra, Krunal Vaghela, Ashish Singh, K S Ravi Kumar, Durga Prasad Bavirisetti

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dawa Chyophel LepchaDepartment of ECE, University Centre for Research and Development, Chandigarh University, Mohali, Punjab, 140413, India.
Bhawna GoyalFaculty of Engineering, Sohar University, Sohar, Oman.
Ayush DograChitkara University Institute of Engineering and Technology, Chitkara University, Rajpura, Punjab, India.
Krunal VaghelaDepartment of Computer Engineering, Faculty of Engineering and Technology, Marwadi University Research Center, Rajkot, Gujarat, 360003, India.
Ashish SinghNIMS School of Electrical and Electronics Engineering, NIMS University Rajasthan, Jaipur, India.
K S Ravi KumarDepartment of Electronics and Communication Engineering, Raghu Engineering College, Visakhapatnam, Andhra Pradesh, 531162, India.
Durga Prasad BavirisettiDepartment of Computer Science, Norwegian University of Science and Technology, Trondheim, Trøndelag, Norway. durga.bavirisetti@ntnu.no.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-dose computed tomography (LDCT) has gained considerable attention for its ability to minimize patients' exposure to radiation thereby reducing the associated cancer risks. However, this reduction in radiation dose often results in degraded image quality due to the presence of noise and artifacts. To address this challenge, the present study proposes an LDCT image denoising method that leverages a pixel-level nonlocal self-similarity (NSS) prior in combination with a nonlocal means algorithm. The NSS prior identifies similar pixels within non-local regions, which proves more feasible and effective than patch-based similarity in enhancing denoising performance. By utilizing this pixel-level prior, the method accurately estimates noise levels and subsequently applies a non-local Haar transform to execute the denoising process. Furthermore, the study incorporates an enhanced version of a recently proposed nonlocal means algorithm. This revised approach uses discrete neighbourhood filtering properties to enable efficient, vectorized, and parallel computation on modern shared-memory platforms thereby reducing computational complexity. Experimental evaluations on publicly available benchmark dataset NIH-AAPM-Mayo Clinic Low-Dose CT Grand Challenge demonstrate that the proposed method effectively suppresses noise and artifacts while preserving critical image details. Both visual and quantitative comparisons confirm that this approach outperforms several state-of-the-art techniques in terms of image quality and denoising efficiency.

Indexed as

Image Processing, Computer-AssistedMedical InformaticsTomography, X-Ray ComputedAlgorithmsArtifactsHumansPhantoms, ImagingRadiation DosageSignal-To-Noise RatioHaar transform (HT)Image denoisingLow-dose computed tomography (LDCT)Medical imagingNonlocal self-similarity (NSS)Normal-dose computed tomography (NDCT)

Identifiers

PMID40646064
PMCPMC12254505

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.