ArticleSpine deformity2025
Impact of a novel patient-specific, patient-matched Bezier parametric curve rod platform on proximal junction biomechanics in an in silico thoracolumbar instrumented fusion model.
Article in Spine deformity, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo evaluate the biomechanical performance of a novel Bezier surface-smoothed transition rod, and to compare it to conventional and stepped rods, focusing on correction capability, spinal stabilization, instrumentation and spinal loading related to risk of proximal junctional kyphosis (PJK).
methodsA spine finite element model with patient-specific 3D spinal geometry (severe sagittal imbalance from thoracolumbar kyphosis) was used. Surgical instrumentation with five rod types was simulated: (1) constant 6.0 mm diameter, (2) stepped 6.0 mm-5.0 mm diameter, (3) Bezier 6.0 mm-5.5 mm-5.0 mm diameter, (4) constant 5.5 mm diameter, and (5) Bezier 5.5 mm-5.0 mm-4.75 mm diameter. Gravitational forces and flexion movements were simulated to compare load transfer between the spine and instrumentation.
resultsAll rod configurations achieved equivalent sagittal correction. Load distribution analysis showed that Bezier rods provided smoother load transitions and better offloading of proximal segments compared to constant diameter rods. The highest moment sustained by the segment adjacent to the instrumentation was observed with the constant 6 mm rod (9N.m), while the Bezier 5.5-5-4.75 mm rod showed the lowest moment (7.5Nm), indicating reduced stress of 16% on the upper adjacent vertebrae. Similarly, the Bezier rods were more effective in offloading pedicle screws up to 45% with respect to the stiffer rod construct, potentially reducing the risk of PJK.
conclusionsThe simulation analysis demonstrates Bezier rods offer promising biomechanical benefits particularly in load distribution and stress reduction at adjacent levels of long thoracolumbar instrumentation. Future efforts will focus on clinical validation and optimization of patient-specific designs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials