Evidence map›Paper›PMID 40642262›Full record

ArticlePlastic and reconstructive surgery. Global open2025

Buttock Augmentation Using Doppler Ultrasound-guided Cannulation for Patient Safety.

Luis F Reyes, Nicole G Echeverry, Hugo A Aguilar, Juan M Velasco, Brian Ramírez, Silvia Villabona, Hector M Serrano, Agustina Varela

Abstract read
In one paragraph

Article in Plastic and reconstructive surgery. Global open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Rectus Abdominis Fat Grafting: Outcomes and Safety.Plastic and reconstructive surgery. Global open · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Luis F ReyesFrom the Majestic Plastic Surgery, Bogota, Colombia.
Nicole G EcheverryFrom the Majestic Plastic Surgery, Bogota, Colombia.
Hugo A AguilarPrivate Practice, Bogota, Colombia.
Juan M VelascoRenew Health Care, Bogota, Colombia.
Brian RamírezResearch Inc., Bogota, Colombia.
Silvia VillabonaClinica Fundacion Oftalmologica de Santander (FOSCAL), Bucaramanga, Santander, Colombia.
Hector M SerranoPrivate Practice, HAV Plastic Surgery, Bucaramanga, Colombia.
Agustina VarelaResearch Inc., Bogota, Colombia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Augmentation gluteoplasty performed through autologous fat grafting is a surgical technique that volumizes the buttock and shapes the gluteal region according to the patient's expectations, but it is one of the most dangerous aesthetic surgical procedures due to the high rate of the complication and mortality. The aim of the study was to assess the safety of subcutaneous gluteal fat grafting using ultrasound-guided cannulation. Methods: A retrospective study of the clinical outcomes of gluteal augmentation with Doppler ultrasound-assisted fat grafting was conducted. The medical records of 177 patients who underwent gluteal augmentation between February and May 2024 were analyzed. Results: In a sample of 177 patients who received gluteal fat grafting, we found that the visualization of perforating arteries had a median of 9 arteries (interquartile range: 2) per buttock. Distribution by quadrants varied among patients. The use of Doppler ultrasound-guided fat grafting was shown to be safe; related complications included 5 patients with hematomas, 2 with seromas, and 1 with suture dehiscence; no cases of infection, deep vein thrombosis, pulmonary embolism, or death were reported. Conclusions: Subcutaneous gluteal lipoinjection with Doppler ultrasound indirect vision is a procedure that meets patient safety standards. It allows visualization of the tissue where the fat is grafted, reducing the risk of developing thrombotic events by identifying risk structures such as the intramuscular plane and vascular structures. Achieving a good aesthetic result and a low complication rate requires prior training in the use of ultrasound specifically for gluteal lipoinjection using Doppler.

Identifiers

PMID40642262
PMCPMC12245335

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.