ArticleJVS-vascular science2025
Evaluating compliance in three-dimensional-printed polymeric vascular grafts compared to human arteries and commercial grafts in a mock circulation loop compliance in three-dimensional-printed polymeric vascular grafts.
Article in JVS-vascular science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- An Automated Modular Platform for Vascular Graft Assessment via Coronary-like Flow-Induced Stimulation.Bioengineering (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Compliance mismatch between native arteries and prosthetic grafts contribute to complications such as neointimal hyperplasia and pseudoaneurysms, leading to reduced graft patency. Three-dimensional (3D) printing offers a promising solution by flexibly customizing mechanical properties using elastic polymers. This study investigates whether 3D-printed polymeric grafts can better replicate native arterial compliance compared with commercial prosthetic grafts. We conducted compliance tests on human aortoiliac arteries, polytetrafluoroethylene (PTFE) grafts, Dacron grafts, and 3D-printed arteries with BioMed Elastic Resin within a mock circulation loop. All samples shared controlled geometry and were tested under the same physiological flow conditions. Pressure waveforms and key hemodynamic parameters were recorded and analyzed. The 3D-printed graft demonstrated a compliance of 0.49 cm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.