ArticleIEEE transactions on medical robotics and bionics2024
Self-Steering Catheters for Neuroendovascular Interventions.
Article in IEEE transactions on medical robotics and bionics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A Review of Peripheral Vascular Intervention Technologies.Journal of clinical medicine · 2026Review
- Serially-Connected Soft Continuum Robots for Endovascular Emergencies.IEEE transactions on medical robotics and bionics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The size limitations and tortuosity of the neurovasculature currently exceed the capabilities of existing robotic systems. Furthermore, safety considerations require a fail-safe design whereby some passive compliance is used for an added layer of safety and for sensing the lateral load on the steerable portion of the catheter. To address these needs, we propose a novel multi-articulated robotic catheter technology that aims to increase technical precision, reduce procedural time and radiation exposure, and enable the semi-automation of catheters during neuroendovascular procedures. This catheter uses joint-level sensing and fluoroscopic imaging to actively bend in two separate planes. Its design also uses series-elastic actuation for increased safety and active compliance (self-steering). We present the design, kinematic modeling, and calibration of this system. A multi-mode real-time control architecture of the system was implemented and experimentally validated. We demonstrate the use of the robotic catheter for branch selection, insertion in an unknown channel under active compliance, and autonomous deployment within a 2D vasculature model. Furthermore, we developed algorithms for intra-operative catheter tracking and pose filtering. Methods presented in this paper make significant strides towards the future goal of enabling semi-autonomous navigation for neuroendovascular procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.