Assessment of Variable Traveling Wave Profiles for Small-Molecule Applications in Ion Mobility Spectrometry-Mass Spectrometry (IMS-MS).

James N Dodds, Amie M Solosky, Sadie M Disselkoen, Kara M Joseph, Erin S Baker

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

James N DoddsDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514, United States.ORCID 0000-0002-9702-2294
Amie M SoloskyDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514, United States.
Sadie M DisselkoenDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514, United States.
Kara M JosephDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514, United States.
Erin S BakerDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514, United States.ORCID 0000-0001-5246-2213

Funding

Single cell, multi-parametric high throughput platform to classify endocrine disruptor potential of mixturesP42ES027704 · NIEHS · TEXAS A&M UNIVERSITY · PI Efstratios Pistikopoulos · 2017 to 2026
$21.2M
Increasing the Coverage, Sensitivity and Specificity of Rapid Lipidomic MeasurementsR01GM141277 · NIGMS · UNIV OF NORTH CAROLINA CHAPEL HILL · PI BAKER, ERIN S · 2022 to 2025
$1.2M
NIEHS NIH HHS P42 ES027704NIGMS NIH HHS R01 GM141277
6 · The paper itself

Abstract

The MOBILion MOBIE system is a relatively new platform offering high ion mobility spectrometry (IMS) resolving power and resolution. While these advancements present encouraging opportunities for isomer separations and improved molecular annotation, previous studies have noted that collision cross section (CCS) values collected on the MOBIE and other traveling wave (TW) systems possess bias in calculated CCS values that limits the functionality of translating CCS libraries across multiple IMS platforms. Though these challenges persist, MOBILion recently released a software update (EyeOn v.2.3) that provides the capability of utilizing variable traveling wave profiles, which modulate the applied TW amplitude and frequency over the duration of each IMS scan to provide optimal transmission, IMS resolution, and scan speed. In this work, 5 variable TW profiles are assessed alongside a legacy "static" method for application toward future small-molecule workflows, tested herein with 3 model systems: per- and polyfluoroalkyl substances (PFAS), bile acids, and oxylipins. Using 3 primary evaluation metrics, including (1) ion transmission, (2) IMS resolution of isomeric species, and (3) relative ease of CCS conversion and mobility filtering, the collective results illustrate that the "Full" TW profile possesses many advantages when analyzing small molecules for nontargeted applications. Although the bias in TW-based CCS measurements vs previous DTIMS values remains, utilizing CCS values obtained with a consistent variable TW profile enables a linear calibration procedure, which facilitates routine mobility filtering of IMS-MS data by CCS and represents a needed improvement for streamlining both data acquisition and subsequent analysis.