ArticleScientific reports2025
Optimizing security and energy efficiency in IoT-Based health monitoring systems for wireless body area networks.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Battery-aware approximate wireless telemetry framework for resilient wearable ECG monitoring under extreme power constraints.Scientific reports · 2026Article
- A translational IoT healthcare framework integrating secure sensing, energy-aware intelligence, and adaptive emergency response.Scientific reports · 2026Article
- Quantum-enhanced privacy aggregation for healthcare monitoring in wireless body area networks.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Wireless Body Area Networks (WBANs) play a critical role in real-time healthcare monitoring by enabling continuous data collection from body-worn sensors. However, energy inefficiency and data security vulnerabilities limit their large-scale deployment and long-term reliability. The primary aim of this research is to optimize both energy consumption and data integrity within WBAN-based health monitoring systems. To address these issues, a novel multi-layered framework is proposed. First, an energy-efficient mechanism is introduced using a threshold-based transmission controller. Each sensor node monitors its power levels and enters sleep mode when a defined energy threshold (0.4 J) is reached. A flag is transmitted to the sink node to indicate potential data unavailability, preventing misinterpretation of sensor silence. Transmission power is dynamically scaled to further minimize energy usage without compromising data delivery. Second, a lightweight security mechanism is incorporated using echo packet validation. A dedicated security block monitors the reverse packet flow for anomalies. Any deviation from the expected flow pattern triggers a breach alert, effectively identifying and mitigating spoofing or reverse-channel attacks. This ensures data integrity and confidentiality across the WBAN. Additionally, a trust aggregation engine is implemented to quantify the trustworthiness of nodes using both global and local ratings. The healthcare provider assigns global ratings, while local ratings are crowdsourced from remote users or monitoring agents. The aggregation logic at the Cluster Head (CH) ensures that only data with validated origin and computation consistency are accepted, significantly increasing trust in remote diagnostics. Simulations were conducted using MATLAB R2022b with 50 nodes across a 20 × 20 m² area. The proposed system achieved a 35% reduction in energy consumption, lowering it from 20 Joules (baseline) to 13 Joules, and improved data accuracy to 98%, compared to 78% and 80% in existing methods. The system also demonstrated a reduction in false positive alerts below 3.8%, a packet delivery ratio of 97.5%, and latency under 92 ms, indicating its real-time applicability and reliability. These results confirm that the proposed framework not only prolongs network lifetime but also secures data communication while maintaining high diagnostic fidelity, thereby offering a robust and scalable solution for next-generation WBAN healthcare applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.