Temperature and Humidity During Different Neonatal Respiratory Support Modes: An In-Vitro Performance of Four Heated Humidifiers.
Article in Pediatric pulmonology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundAdequate heating and humidification of inspired gas are crucial in preterm infants requiring respiratory support. Our objective was to compare the temperature (T) and absolute humidity (AH) achieved with different neonatal heated humidifiers commonly used during different respiratory support modes and respiratory settings.
methodsFour neonatal heated humidifiers were tested at different gas flow rates and during conventional and high-frequency oscillatory ventilation at clinically relevant settings. The patient was simulated using a neonatal test lung placed in a neonatal incubator warmed at 37°C. Temperature and relative humidity were measured using a thermohygrometer placed proximal to the test lung and used to calculate AH.
resultsMeasured temperature and humidity varied among heated humidifiers and respiratory support settings. The bias flow was the primary determinant of the measured temperature and humidity: temperature and AH significantly increased with flow. When the flow through the chamber was below 5 L/min the MR950 produced T < 36.7°C and AH < 37 g/m
conclusionThe temperature and humidity proximal to the patients' airways might vary considerably based on the heated humidifiers and the flow through the chamber. Further clinical studies are needed to evaluate the effect of such variability on the patients.