Evidence map›Paper›PMID 40636091›Full record

ArticleiLIVER2024

Short-term effects of modified ultrasonography in laparoscopic anatomical hepatectomy for hepatocellular carcinoma.

Xun Wang, Xuan Meng, Liming Wang, Peng Wang, Zhihao Wang, Weiqi Rong, Zhiyu Lu, Hongguang Wang

Abstract read
In one paragraph

Article in iLIVER, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xun WangDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Xuan MengDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Liming WangDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Peng WangDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Zhihao WangDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Weiqi RongDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Zhiyu LuDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
Hongguang WangDepartment of Hepatobiliary Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and aims: Laparoscopic hepatectomy is challenging, and ultrasound guidance is an effective aid but lacks standardization. This study aimed to evaluate a modified approach for laparoscopic ultrasonography to enhance surgical outcomes. Methods: Between January 2020 and August 2023, 122 patients who underwent real-time ultrasound-guided laparoscopic anatomical hepatectomy for hepatocellular carcinoma were enrolled and divided into modified and traditional ultrasonography groups. The modified ultrasound application comprised intraoperative protocol-based laparoscopic ultrasonography comprising application scenarios; standardized positions for the surgeon, trocar, and probe; and the resulting standardized sections for various laparoscopic liver resections. Clinical characteristics and perioperative outcomes were compared between the two groups. Subgroup analysis was performed and comprised techniques for modified duct structure identification and portal vein branch puncture; both techniques were used in fluorescence probe-mounted laparoscopic liver resection using negative and positive staining procedures, respectively. Results: The traditional and modified groups comprised 64 and 58 patients, respectively. The patients' background characteristics were not significantly different between the groups. Surgical duration (283.4 min vs. 225.1 min; Conclusions: Modified ultrasonography improves the safety and effectiveness of laparoscopic hepatectomy. Ultrasonography is pivotal, especially in fluorescence probe-assisted laparoscopic liver resection.

Indexed as

Anatomical hepatectomyHepatocellular carcinomaLaparoscopic ultrasoundModified ultrasound guidance

Identifiers

PMID40636091
PMCPMC12212690

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.