Evidence map›Paper›PMID 40631954›Full record

ArticleACS applied materials & interfaces2025

Flexible Depth Probes with PEDOT:PSS Microelectrodes for Chronic Recording and Stimulation.

Rémy Cornuéjols, Anton Ivanov, Antoine Ghestem, Amélie Albon, Charline Ytier, Mathilde Nordlund, Jules Mercier, Christophe Bernard, Shahab Rezaei-Mazinani

Abstract read
In one paragraph

Article in ACS applied materials & interfaces, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. PEDOT:PSS-A Key Material for Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rémy CornuéjolsINSERM, INS, Inst Neurosci Syst, Aix Marseille University, 13005 Marseille, France.
Anton IvanovINSERM, INS, Inst Neurosci Syst, Aix Marseille University, 13005 Marseille, France.
Antoine GhestemINSERM, INS, Inst Neurosci Syst, Aix Marseille University, 13005 Marseille, France.
Amélie AlbonCentre CMP, Departement BEL, Mines Saint-Etienne, F-13541 Gardanne, France.
Charline YtierINSERM, INS, Inst Neurosci Syst, Aix Marseille University, 13005 Marseille, France.
Mathilde NordlundINSERM, INS, Inst Neurosci Syst, Aix Marseille University, 13005 Marseille, France.
Jules MercierCentre CMP, Departement BEL, Mines Saint-Etienne, F-13541 Gardanne, France.
Christophe BernardINSERM, INS, Inst Neurosci Syst, Aix Marseille University, 13005 Marseille, France.
Shahab Rezaei-MazinaniCentre CMP, Departement BEL, Mines Saint-Etienne, F-13541 Gardanne, France.ORCID 0000-0002-7868-4540

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Flexible neural probes with conductive polymer electrodes present promising alternatives to rigid devices for chronic brain stimulation and recording. Organic devices, characterized by higher charge injection capabilities and better compatibility with biological tissues compared to inorganic probes, hold significant potential in this field. However, demonstrating stability and consistent physiological responses during prolonged pulsing is crucial for their practical application. Moreover, their implantation into brain tissue remains a challenge. Due to their small size and flexibility, organic devices are difficult to insert into brain tissue. This limits their widespread use for recording and deep stimulation of the brain. In this study, we fabricated plastic depth probes with PEDOT:PSS electrodes and developed a reliable protocol for their implantation into brain tissue using a stiff, removable shuttle. We implanted two identical probes into the hippocampus of an adult rat, targeting the CA1 layer with recording electrodes and Schaffer collaterals with stimulating electrodes. We demonstrated that these fabricated devices are excellent tools for recording not only the activity of the neuronal network but also individual neurons. Using microampere range electrical current pulses, we stimulated Schaffer collaterals in freely moving rats and recorded the electrophysiological responses of CA1 pyramidal cells over a 12 day period. Histological analysis of the implanted brain revealed that the lesions caused by our probes were significantly smaller than those left by metal electrodes. Thus, we demonstrated that flexible organic devices are highly effective tools for deep brain recording and stimulation.

Indexed as

Bridged Bicyclo Compounds, HeterocyclicPolymersPolystyrenesThiophenesAnimalsElectric StimulationElectrodes, ImplantedMaleMicroelectrodesPyramidal CellsRatsRats, Sprague-DawleyBridged Bicyclo Compounds, Heterocyclicpoly(3,4-ethylene dioxythiophene)poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)PolymersPolystyrenesThiophenesbioelectronicschronicmicroelectrode arraysneural interface devicesneural microstimulationneural recordingsthin-film polymers

Identifiers

PMID40631954
PMCPMC12291092

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked