Evidence map›Paper›PMID 40630901›Full record

ArticleFrontiers in cardiovascular medicine2025

Retrieval of an IVCF retained for over 6 years via femoral venous approach using a large-bore sheath: a case report and literature review.

Gang Yuan, Wei Hu, Weiming Wang, Yanneng Xu, Ran Cui, Xun Zhang, Jianming Luo, Guangyan Si

Abstract readCase Reports
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gang Yuan *Department of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.
Wei Hu *Department of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.
Weiming Wang *Department of General Surgery (Vascular Surgery), The Affiliated Hospital of Southwest Medical University, Luzhou, China.
Yanneng XuDepartment of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.
Ran CuiDepartment of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.
Xun ZhangDepartment of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.
Jianming LuoDepartment of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.
Guangyan SiDepartment of Intervention & Vascular, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Prolonged retention of inferior vena cava filters (IVCF) predisposes patients to complications, including caval thrombosis, filter tilt, wall adherence, fibrotic adhesion, migration, and perforation, posing significant risks to patient health. Retrieval of long-term retained filters is challenging, as standard retrieval techniques often prove ineffective. Advanced strategies are therefore required to improve success rates. Herein, we report a case of an IVCF retained for over 6 years, in which the patient developed acute thrombosis of the inferior vena cava (IVC) and iliac veins following recent discontinuation of anticoagulation. Concurrently, the retrieval hook was embedded in fibrotic tissue with wall apposition, and the filter struts had perforated the vascular wall with dense adhesions. Initial attempts using a standard retrieval kit failed. Subsequently, a loop snare technique was employed to dissect perihook fibrotic tissue, successfully engaging the retrieval hook. However, due to the filter's firm incorporation into the IVC, the hook straightened under traction, resulting in retrieval failure. Ultimately, the stubborn filter was successfully removed via a retrograde approach using a 20F vascular sheath through the femoral vein. By detailing this case and reviewing relevant literature, we aim to provide insights into advanced retrieval strategies for challenging IVCF, particularly those with prolonged dwell times.

Indexed as

case reportinferior vena cava filterlarge-bore vascular sheathprolonged retentionretrieval

Identifiers

PMID40630901
PMCPMC12234304

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.