ArticleJournal of orthodontic science2025
Finite element analysis of the transpalatal arch force systems activated in the Burstone geometries with different materials.
Article in Journal of orthodontic science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aim of the studyThis research paper was intended to quantify the stresses and the displacement distribution pattern released by Omega-loop transpalatal arch (TPA) activated in the Burstone geometries (II, III, and V) within two different materials. MATERIALS AND
methodsThree-dimensional solid models of the maxilla and maxillary teeth were created using CBCT data for a 20-year-old man. A molar band and Omega-loop TPA were constructed. Force application was pretended virtually to geometry II, III, and V within stainless-steel and Armco β-titanium (TMA) (titanium-molybdenum-aluminum) material.
resultsThe schemes for stresses and the displacements were alike for both stainless-steel and TMA alloy Omega-loop TPAs. The stresses and displacements for the stainless-steel Omega-loop TPAs were higher than those for the TMA. Mesial tipping was seen in the unit with a large moment, distally in the opposite side. The highest displacement values were seen around the x-axis, which represent the tipping molar movement.
conclusionsThis study results have shown that Omega-loop TPA can effectively derotate upper first molars. Anchorage reinforcement for the opposite molar should be kept in the orthodontist mind to avoid the unwanted movement as a result of the reactive forces for the active unit, especially when it is decided to use a high force to correct unilateral molar rotation.