Evidence map›Paper›PMID 40630033›Full record

ArticleInternational journal for numerical methods in biomedical engineering2025

Enhancing Imaging Performance and Resolution in Magneto-Acoustic Electrical Tomography With Magnetic Field Measurements (MAET-MI) Using Figure-of-Eight and High-Quality Factor Circular Coils.

Ahmet Önder Tetik, Nevzat Güneri Gençer

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ahmet Önder TetikElectrical and Electronics Engineering Department, Middle East Technical University, Ankara, Türkiye.ORCID https://orcid.org/0009-0009-7178-2218
Nevzat Güneri GençerElectrical and Electronics Engineering Department, Middle East Technical University, Ankara, Türkiye.ORCID https://orcid.org/0000-0002-4776-7968

Funding

Scientific and Technological Research Council of Türkiye (TÜBİTAK) 119E126
6 · The paper itself

Abstract

Magneto-acousto-electrical tomography with magnetic field measurement technique (MAET-MI) is a hybrid imaging method that brings high spatial resolution of ultrasound imaging in electrical impedance tomography. This study investigates the impact of the quality factor of circular and figure-of-eight coils on the imaging performance of MAET-MI. Induced MAET signals on the circular coil are accurately obtained by modeling a circuit representation of an air-cored circular coil and deriving its transfer function through impedance measurements. The study demonstrates a significant improvement in signal-to-noise ratio (SNR) using high-quality factor coils compared to unity quality factor coils. Additionally, a 16-element linear phased array (LPA) ultrasound transducer, an air core circular coil, and a figure-of-eight coil are numerically modeled to obtain sector scan images of two-dimensional conductivity distributions. Point spread function (PSF) is characterized, and the lateral resolution of sector scan conductivity images is enhanced through two-dimensional deconvolution with PSF. The combined use of circular and figure-of-eight coils provides comprehensive imaging coverage. Notably, this research presents a practical method for estimating both circular and figure-of-eight coils' transfer functions, achieving 12.9 dB SNR improvement with high-quality factor coils. A simplified breast model is rotated 16 steps, and sector scan conductive boundary images are reconstructed for both coils. A two-dimensional image of a breast model is obtained by combining images from two different coils. These findings offer significant advancements in MAET-MI imaging, particularly in low SNR environments.

Indexed as

Magnetic FieldsTomographyElectric ImpedanceHumansPhantoms, ImagingSignal-To-Noise Ratiocoildelay‐and‐sum methodmagneto‐acousto‐electrical tomographyultrasound imagingwiener filter

Identifiers

PMID40630033
PMCPMC12238840

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.