ArticlePloS one2025
Addressing the barriers to peritoneal dialysis-Visual appeal matters.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Peritoneal dialysis (PD) is an effective renal replacement strategy for patients with end-stage renal disease utilizing the peritoneum as the filter and PD catheter as access. A survey of PD patients showed that some felt uncomfortable with the length of current catheters and would be interested to explore newer, shorter designs. We redesigned the transfer set and external portion of the catheter, addressing this barrier as a part of our multi-institutional design project led by a nephrologist from the University of Arkansas for Medical Sciences (UAMS) and an engineering design team from the biomedical engineering department at the University of Arkansas. Multiple designs were considered, including spiral, retractable, and collapsible bulbs, with an accordion-style mechanism being selected for prototyping. We created several prototypes, first by 3D printing as well as by silicone casting. Computational fluid analysis showed the design to be fully capable of delivering clinically relevant flows. The final design of our PD transfer set has a flexible accordion section that is 7 cm when extended and collapses to substantially shorten this length. We propose that the design can also be extended to the extra-abdominal section of the PD catheter.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.