Evidence map›Paper›PMID 40622614›Full record

ArticleJapanese journal of radiology2025

Performance of a deep-learning-based lung nodule detection system using 0.25-mm thick ultra-high-resolution CT images.

Haruka Higashibori, Wataru Fukumoto, Sayaka Kusuda, Kazushi Yokomachi, Hidenori Mitani, Yuko Nakamura, Kazuo Awai

Abstract read
In one paragraph

Article in Japanese journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Haruka HigashiboriDepartment of Diagnostic Radiology, Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan.
Wataru FukumotoDepartment of Diagnostic Radiology, Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan. wfukumoto@hiroshima-u.ac.jp.ORCID http://orcid.org/0000-0001-7645-8446
Sayaka KusudaDepartment of Diagnostic Radiology, Hiroshima University Hospital, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan.
Kazushi YokomachiDepartment of Diagnostic Radiology, Hiroshima University Hospital, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan.
Hidenori MitaniDepartment of Diagnostic Radiology, Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan.
Yuko NakamuraDepartment of Diagnostic Radiology, Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan.
Kazuo AwaiDepartment of Diagnostic Radiology, Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3 Kasumi, Minamiku, Hiroshima, 734-8551, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeArtificial intelligence (AI) algorithms for lung nodule detection assist radiologists. As their performance using ultra-high-resolution CT (U-HRCT) images has not been evaluated, we investigated the usefulness of 0.25-mm slices at U-HRCT using the commercially available deep-learning-based lung nodule detection (DL-LND) system. MATERIALS AND

methodsWe enrolled 63 patients who underwent U-HRCT for lung cancer and suspected lung cancer. Two board-certified radiologists identified nodules more than 4 mm in diameter on 1-mm HRCT slices and set the reference standard consensually. They recorded all lesions detected on 5-, 1-, and 0.25-mm slices by the DL-LND system. Unidentified nodules were included in the reference standard. To examine the performance of the DL-LND system, the sensitivity, and positive predictive value (PPV) and the number of false positive (FP) nodules were recorded.

resultsThe mean number of lesions detected on 5-, 1-, and 0.25-mm slices was 5.1, 7.8 and 7.2 per CT scan. On 5-mm slices the sensitivity and PPV were 79.8% and 46.4%; on 1-mm slices they were 91.5% and 34.8%, and on 0.25-mm slices they were 86.7% and 36.1%. The sensitivity was significantly higher on 1- than 5-mm slices (p < 0.01) while the PPV was significantly lower on 1- than 5-mm slices (p < 0.01). A slice thickness of 0.25 mm failed to improve its performance. The mean number of FP nodules on 5-, 1-, and 0.25-mm slices was 2.8, 5.2, and 4.7 per CT scan.

conclusionWe found that 1 mm was the best slice thickness for U-HRCT images using the commercially available DL-LND system.

Indexed as

Deep LearningLung NeoplasmsRadiographic Image Interpretation, Computer-AssistedSolitary Pulmonary NoduleTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHumansLungMaleMiddle AgedRetrospective StudiesSensitivity and SpecificityArtificial intelligenceComputer-aided detectionLung noduleUltra-high-resolution CT

Identifiers

PMID40622614
PMCPMC12575579

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.