Evidence map›Paper›PMID 40622086›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025

Total knee replacement designs have differing stability under novel robotic testing method in vitro.

Sander R Holthof, Shuntaro Nejima, Mick Rock, Richard Jan vanArkel, Angela Brivio, David Barrett, Andrew A Amis

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Total knee replacement designs have differing stability under novel robotic testing method in vitro.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sander R HolthofDepartment of Mechanical Engineering, Biomechanics Group, Imperial College London, London, UK.
Shuntaro NejimaDepartment of Mechanical Engineering, Biomechanics Group, Imperial College London, London, UK.
Mick RockDe Puy Synthes Ltd, Leeds, UK.
Richard Jan vanArkelDepartment of Mechanical Engineering, Biomechanics Group, Imperial College London, London, UK.
Angela BrivioDepartment of Trauma and Orthopedic Surgery, Istituto Clinico Città Studi, Milano, Italy.
David BarrettKing Edward VII hospital, London, UK.
Andrew A AmisDepartment of Mechanical Engineering, Biomechanics Group, Imperial College London, London, UK.ORCID https://orcid.org/0000-0002-4489-1381

Funding

De Puy Synthes Ltd
6 · The paper itself

Abstract

purposeThis study implemented a novel robotic test method to quantify the effect of three distinct total knee arthroplasty (TKA) designs on knee kinematics and stability. It was hypothesised that the implant geometries would affect stability and rollback, with differences between the native and replaced knees, as well as between implant designs.

methodsEight fresh-frozen cadaveric knees were tested across the arc of flexion-extension under 710 N compressive load, combined with either no anterior-posterior (AP) tibial force, 90 N anterior or 90 N posterior drawer force using a robotic actuator. The same testing protocol was used post-TKA using three distinct implant designs (gradually reducing femoral condylar radius medially stabilised, multi-radius medially conforming and single-radius symmetrical), matched to the same bone cuts. Laxity and rollback were analysed using statistical parametric mapping and implant designs were compared to the intact knee and each other.

resultsNo significant differences in AP laxity were found between the intact knee (4.7 ± 0.7 mm), gradually reducing radius (6.3 ± 1.3 mm) and multi-radius designs (5.7 ± 1.1 mm). The single-radius implant showed significantly larger average AP laxity envelope (11.6 ± 2.3 mm) than the intact knee, the multi-radius design and the gradually reducing radius design and was more variable between knees. The rollback among the intact knee and TKAs were not significantly different: gradual radius 81% of native, multi-radius 85% and single-radius 90%.

conclusionsSignificant differences of AP laxity were found between the pre- and post TKA knee and between implant designs. Rollback did not differ significantly. Implanted knee behaviour also showed differences of sensitivity to cadaveric specimen and implantation variation among the prosthesis designs. CLINICAL RELEVANCE: Instability post-TKA remains an issue for good patient outcomes. Robotic testing of implanted knees shows the effects of implant design on knee stability and motion, potentially improving outcomes by providing the surgeon with objective data on which to base their choice of TKA. LEVEL OF EVIDENCE: N/A. Controlled laboratory study.

Indexed as

Arthroplasty, Replacement, KneeJoint InstabilityKnee JointKnee ProsthesisProsthesis DesignRoboticsAgedAged, 80 and overBiomechanical PhenomenaCadaverFemaleHumansMaleMiddle AgedRange of Motion, Articularkinematicsprosthesis articular geometryrobot testingstability testingtotal knee arthroplasty

Identifiers

PMID40622086
PMCPMC12582242

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.