Evidence map›Paper›PMID 40622067›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025

Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double-blinded controlled radiostereometry trial with 24 months of follow-up.

Carl Christian Holkgaard Burvil, Karina Nørgaard Linde, Maiken Stilling, Torben Bæk Hansen, Jesper Dalsgaard, Søren Rytter, Daan Koppens, Emil Toft Petersen

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Carl Christian Holkgaard BurvilAutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.ORCID https://orcid.org/0009-0004-3553-6689
Karina Nørgaard LindeAutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.ORCID https://orcid.org/0000-0002-2523-9128
Maiken StillingAutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.ORCID https://orcid.org/0000-0002-4530-2075
Torben Bæk HansenDepartment of Clinical Medicine, Aarhus University, Aarhus, Denmark.ORCID https://orcid.org/0000-0003-1678-3612
Jesper DalsgaardUniversity Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Gødstrup, Denmark.
Søren RytterDepartment of Orthopedic Surgery, Aarhus University Hospital, Aarhus N, Denmark.ORCID https://orcid.org/0000-0001-5757-6623
Daan KoppensDepartment of Orthopedic Surgery, Aarhus University Hospital, Aarhus N, Denmark.ORCID https://orcid.org/0000-0001-6486-6012
Emil Toft PetersenAutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.ORCID https://orcid.org/0000-0003-1697-8778

Funding

Aarhus UniversityKøbmand Sven Hansen og Hustru Ina Hansens FondSøster og Verner Lipperts FondThe Danish Rheumatism AssociationToyota-Fonden
6 · The paper itself

Abstract

purposeTo assess the influence of a higher constraint medial congruent (MC) versus a cruciate retaining (CR) (gold standard) polyethylene insert on the migration of cemented tibial and femoral components of the Persona Total Knee System. High-constraint inserts may increase forces on components and potentially affect implant migration and long-term fixation.

methodsA cohort of 66 patients with primary knee osteoarthritis received a cemented Persona total knee arthroplasty and were randomised to either an MC or a CR polyethylene insert. Tibial and femoral component migration was assessed using static radiostereometric analysis, with the first stereo-radiograph taken supine on the first postoperative day (baseline) and again at 3-, 12-, and 24-month follow-up. Tibial and femoral component migration was evaluated in six degrees of freedom and as maximum total point motion (MTPM).

resultsAt the 12-month follow-up, the mean difference in tibial component MTPM was 0.04 mm (95% confidence interval [CI]: -0.21 to 0.28). The mean MTPM was 0.81 mm (95% CI: 0.64-0.99) in the MC group and 0.85 mm (95% CI: 0.68-1.03) in the CR group. Signed migrations were similar for the MC and the CR group throughout 24 months of follow-up (p > 0.09). At the 12-month follow-up, the mean difference in femoral component MTPM was 0.18 mm (95% CI: -0.17 to 0.53). The mean MTPM was 1.08 mm (95% CI: 0.83-1.32) in the MC group and 1.26 mm (95% CI: 1.01-1.51) in the CR group. The femoral components with MC insert had 0.18 mm (95% CI: 0.03-0.32) and 0.20 mm (95% CI: 0.01-0.39) more lateral migration at 3- and 12-month follow-up, respectively. At the 24-month follow-up, there was no statistically significant differences in migration for either translations, rotations or MTPM.

conclusionsBoth tibial and femoral components had similar and acceptable fixation regardless of the type of polyethylene insert. LEVEL OF EVIDENCE: Level I.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeAgedDouble-Blind MethodFemaleFollow-Up StudiesHumansKnee JointMaleMiddle AgedPolyethyleneProsthesis DesignProsthesis FailureRadiostereometric AnalysisRange of Motion, ArticularPolyethylenemedial congruentmigrationradiostereometryRSAtotal knee arthroplasty

Identifiers

PMID40622067
PMCPMC12582241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.