Evidence map›Paper›PMID 40621362›Full record

ArticleCureus2025

Feasibility and Confidence in Carotid Spectral Doppler for Pulse Detection: Training Outcomes Among Emergency Medicine Residents.

Jeremy Carter, Connor Babbush, Ian Coe, Stephen Haight, Javier Andrade, Josie Acuña, Srikar Adhikari

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jeremy CarterEmergency Medicine, University of Texas Medical Branch, Galveston, USA.
Connor BabbushEmergency Medicine, University of Arizona, Tucson, USA.
Ian CoeInternal Medicine, University of Arizona, Tucson, USA.
Stephen HaightEmergency Medicine, University of California, San Francisco, Fresno, Fresno, USA.
Javier AndradeEmergency Medicine, Abrazo Health, Phoenix, USA.
Josie AcuñaEmergency Medicine, University of Arizona, Tucson, USA.
Srikar AdhikariEmergency Medicine, University of Arizona, Tucson, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Carotid ultrasound has demonstrated utility in identifying the presence of a pulse, particularly in cardiac arrest. Despite this evidence, there is currently no existing literature that focuses on the training of physicians in this modality for the purpose of pulse detection. The primary objective of this study is to demonstrate that novice ultrasound users with varying levels of training can be taught a simple and repeatable method for identifying flow in the common carotid artery (CCA) using a combination of B-mode ultrasound and spectral Doppler. The secondary objective is to evaluate the confidence of emergency medicine (EM) residents with varying levels of ultrasound experience in accurately identifying the carotid pulse using spectral Doppler. Methods This is a cross-sectional study, using a convenience sample of emergency medicine (EM) residents. Residents with varying levels of ultrasound experience received training on obtaining CCA ultrasound images and spectral Doppler. Subjects were then asked to image the common carotid artery and obtain a spectral Doppler waveform on a standardized patient. Expert sonologists observed participants' imaging in real time and recorded their performance. Participants completed a post-questionnaire detailing the number of previous ultrasound examinations they had performed and their comfort level with the carotid ultrasound technique. Results Thirty-eight residents participated in the study. The residents were able to obtain a spectral Doppler waveform from the CCA in 38 (100%) of cases, and 35 (92%) residents were able to perform this task without any assistance from the instructor. The average time to obtain a waveform was 23 seconds. Twelve (32%) residents were able to obtain a pulse within 15 seconds. After the training session, 37 (97%) residents felt comfortable identifying arterial flow in the CCA using spectral Doppler and would feel comfortable using this technique on an actual patient receiving cardiopulmonary resuscitation (CPR). Conclusion Spectral Doppler of the CCA may be a reasonable alternative for identifying return of spontaneous circulation (ROSC) during pulse check of patients receiving CPR. All residents were able to identify pulses using spectral Doppler, following a brief lecture, instructional video, and hands-on training session.

Indexed as

bedside ultrasoundcardiac arrestcarotid dopplermedical educationpoint-of-care-ultrasoundreturn of spontaneous circulation (rosc)

Identifiers

PMID40621362
PMCPMC12227178

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.